J1939 SPN/FMI Diagnostic Center
924 SPN/FMI technical references for trucks, buses, agricultural, construction, marine and industrial systems.
SPN identifies the monitored parameter/system while FMI separates the fault mode observed by the controller. The same SPN can require a completely different test sequence under another FMI.
SPN 84 FMI 0: Wheel-Based Vehicle Speed - Data Valid But Above Normal Operational Range
→vehicle_speedSPN84-FMI1SPN 84 FMI 1: Wheel-Based Vehicle Speed - Data Valid But Below Normal Operational Range
→vehicle_speedSPN84-FMI2SPN 84 FMI 2: Wheel-Based Vehicle Speed - Data Erratic, Intermittent or Incorrect
→vehicle_speedSPN84-FMI3SPN 84 FMI 3: Wheel-Based Vehicle Speed - Voltage Above Normal or Shorted High
→vehicle_speedSPN84-FMI4SPN 84 FMI 4: Wheel-Based Vehicle Speed - Voltage Below Normal or Shorted Low
→vehicle_speedSPN84-FMI5SPN 84 FMI 5: Wheel-Based Vehicle Speed - Current Below Normal or Open Circuit
→vehicle_speedSPN84-FMI6SPN 84 FMI 6: Wheel-Based Vehicle Speed - Current Above Normal or Grounded Circuit
→vehicle_speedSPN84-FMI7SPN 84 FMI 7: Wheel-Based Vehicle Speed - Mechanical System Not Responding Properly
→vehicle_speedSPN84-FMI8SPN 84 FMI 8: Wheel-Based Vehicle Speed - Abnormal Frequency, Pulse Width or Period
→vehicle_speedSPN84-FMI9SPN 84 FMI 9: Wheel-Based Vehicle Speed - Abnormal Update Rate
→vehicle_speedSPN84-FMI10SPN 84 FMI 10: Wheel-Based Vehicle Speed - Abnormal Rate of Change
→vehicle_speedSPN84-FMI11SPN 84 FMI 11: Wheel-Based Vehicle Speed - Root Cause Not Known
→vehicle_speedSPN84-FMI12SPN 84 FMI 12: Wheel-Based Vehicle Speed - Bad Intelligent Device or Component
→vehicle_speedSPN84-FMI13SPN 84 FMI 13: Wheel-Based Vehicle Speed - Out of Calibration
→vehicle_speedSPN84-FMI14SPN 84 FMI 14: Wheel-Based Vehicle Speed - Special Instructions
→vehicle_speedSPN84-FMI15SPN 84 FMI 15: Wheel-Based Vehicle Speed - Above Normal Range - Least Severe
→vehicle_speedSPN84-FMI16SPN 84 FMI 16: Wheel-Based Vehicle Speed - Above Normal Range - Moderately Severe
→vehicle_speedSPN84-FMI17SPN 84 FMI 17: Wheel-Based Vehicle Speed - Below Normal Range - Least Severe
→vehicle_speedSPN84-FMI18SPN 84 FMI 18: Wheel-Based Vehicle Speed - Below Normal Range - Moderately Severe
→vehicle_speedSPN84-FMI19SPN 84 FMI 19: Wheel-Based Vehicle Speed - Received Network Data In Error
→vehicle_speedSPN84-FMI31SPN 84 FMI 31: Wheel-Based Vehicle Speed - Condition Exists
→engine_controlSPN91-FMI0SPN 91 FMI 0: Accelerator Pedal Position - Data Valid But Above Normal Operational Range
→engine_controlSPN91-FMI1SPN 91 FMI 1: Accelerator Pedal Position - Data Valid But Below Normal Operational Range
→engine_controlSPN91-FMI2SPN 91 FMI 2: Accelerator Pedal Position - Data Erratic, Intermittent or Incorrect
→engine_controlSPN91-FMI3SPN 91 FMI 3: Accelerator Pedal Position - Voltage Above Normal or Shorted High
→engine_controlSPN91-FMI4SPN 91 FMI 4: Accelerator Pedal Position - Voltage Below Normal or Shorted Low
→engine_controlSPN91-FMI5SPN 91 FMI 5: Accelerator Pedal Position - Current Below Normal or Open Circuit
→engine_controlSPN91-FMI6SPN 91 FMI 6: Accelerator Pedal Position - Current Above Normal or Grounded Circuit
→engine_controlSPN91-FMI7SPN 91 FMI 7: Accelerator Pedal Position - Mechanical System Not Responding Properly
→engine_controlSPN91-FMI8SPN 91 FMI 8: Accelerator Pedal Position - Abnormal Frequency, Pulse Width or Period
→engine_controlSPN91-FMI9SPN 91 FMI 9: Accelerator Pedal Position - Abnormal Update Rate
→engine_controlSPN91-FMI10SPN 91 FMI 10: Accelerator Pedal Position - Abnormal Rate of Change
→engine_controlSPN91-FMI11SPN 91 FMI 11: Accelerator Pedal Position - Root Cause Not Known
→engine_controlSPN91-FMI12SPN 91 FMI 12: Accelerator Pedal Position - Bad Intelligent Device or Component
→engine_controlSPN91-FMI13SPN 91 FMI 13: Accelerator Pedal Position - Out of Calibration
→engine_controlSPN91-FMI14SPN 91 FMI 14: Accelerator Pedal Position - Special Instructions
→engine_controlSPN91-FMI15SPN 91 FMI 15: Accelerator Pedal Position - Above Normal Range - Least Severe
→engine_controlSPN91-FMI16SPN 91 FMI 16: Accelerator Pedal Position - Above Normal Range - Moderately Severe
→engine_controlSPN91-FMI17SPN 91 FMI 17: Accelerator Pedal Position - Below Normal Range - Least Severe
→engine_controlSPN91-FMI18SPN 91 FMI 18: Accelerator Pedal Position - Below Normal Range - Moderately Severe
→engine_controlSPN91-FMI19SPN 91 FMI 19: Accelerator Pedal Position - Received Network Data In Error
→engine_controlSPN91-FMI31SPN 91 FMI 31: Accelerator Pedal Position - Condition Exists
→fuelSPN94-FMI0SPN 94 FMI 0: Fuel Delivery Pressure - Data Valid But Above Normal Operational Range
→fuelSPN94-FMI1SPN 94 FMI 1: Fuel Delivery Pressure - Data Valid But Below Normal Operational Range
→fuelSPN94-FMI2SPN 94 FMI 2: Fuel Delivery Pressure - Data Erratic, Intermittent or Incorrect
→fuelSPN94-FMI3SPN 94 FMI 3: Fuel Delivery Pressure - Voltage Above Normal or Shorted High
→fuelSPN94-FMI4SPN 94 FMI 4: Fuel Delivery Pressure - Voltage Below Normal or Shorted Low
→fuelSPN94-FMI5SPN 94 FMI 5: Fuel Delivery Pressure - Current Below Normal or Open Circuit
→fuelSPN94-FMI6SPN 94 FMI 6: Fuel Delivery Pressure - Current Above Normal or Grounded Circuit
→fuelSPN94-FMI7SPN 94 FMI 7: Fuel Delivery Pressure - Mechanical System Not Responding Properly
→fuelSPN94-FMI8SPN 94 FMI 8: Fuel Delivery Pressure - Abnormal Frequency, Pulse Width or Period
→fuelSPN94-FMI9SPN 94 FMI 9: Fuel Delivery Pressure - Abnormal Update Rate
→fuelSPN94-FMI10SPN 94 FMI 10: Fuel Delivery Pressure - Abnormal Rate of Change
→fuelSPN94-FMI11SPN 94 FMI 11: Fuel Delivery Pressure - Root Cause Not Known
→fuelSPN94-FMI12SPN 94 FMI 12: Fuel Delivery Pressure - Bad Intelligent Device or Component
→fuelSPN94-FMI13SPN 94 FMI 13: Fuel Delivery Pressure - Out of Calibration
→fuelSPN94-FMI14SPN 94 FMI 14: Fuel Delivery Pressure - Special Instructions
→fuelSPN94-FMI15SPN 94 FMI 15: Fuel Delivery Pressure - Above Normal Range - Least Severe
→fuelSPN94-FMI16SPN 94 FMI 16: Fuel Delivery Pressure - Above Normal Range - Moderately Severe
→fuelSPN94-FMI17SPN 94 FMI 17: Fuel Delivery Pressure - Below Normal Range - Least Severe
→fuelSPN94-FMI18SPN 94 FMI 18: Fuel Delivery Pressure - Below Normal Range - Moderately Severe
→fuelSPN94-FMI19SPN 94 FMI 19: Fuel Delivery Pressure - Received Network Data In Error
→fuelSPN94-FMI31SPN 94 FMI 31: Fuel Delivery Pressure - Condition Exists
→fuelSPN97-FMI0SPN 97 FMI 0: Water In Fuel Indicator - Data Valid But Above Normal Operational Range
→fuelSPN97-FMI1SPN 97 FMI 1: Water In Fuel Indicator - Data Valid But Below Normal Operational Range
→fuelSPN97-FMI2SPN 97 FMI 2: Water In Fuel Indicator - Data Erratic, Intermittent or Incorrect
→fuelSPN97-FMI3SPN 97 FMI 3: Water In Fuel Indicator - Voltage Above Normal or Shorted High
→fuelSPN97-FMI4SPN 97 FMI 4: Water In Fuel Indicator - Voltage Below Normal or Shorted Low
→fuelSPN97-FMI5SPN 97 FMI 5: Water In Fuel Indicator - Current Below Normal or Open Circuit
→fuelSPN97-FMI6SPN 97 FMI 6: Water In Fuel Indicator - Current Above Normal or Grounded Circuit
→fuelSPN97-FMI7SPN 97 FMI 7: Water In Fuel Indicator - Mechanical System Not Responding Properly
→fuelSPN97-FMI8SPN 97 FMI 8: Water In Fuel Indicator - Abnormal Frequency, Pulse Width or Period
→fuelSPN97-FMI9SPN 97 FMI 9: Water In Fuel Indicator - Abnormal Update Rate
→fuelSPN97-FMI10SPN 97 FMI 10: Water In Fuel Indicator - Abnormal Rate of Change
→fuelSPN97-FMI11SPN 97 FMI 11: Water In Fuel Indicator - Root Cause Not Known
→fuelSPN97-FMI12SPN 97 FMI 12: Water In Fuel Indicator - Bad Intelligent Device or Component
→fuelSPN97-FMI13SPN 97 FMI 13: Water In Fuel Indicator - Out of Calibration
→fuelSPN97-FMI14SPN 97 FMI 14: Water In Fuel Indicator - Special Instructions
→fuelSPN97-FMI15SPN 97 FMI 15: Water In Fuel Indicator - Above Normal Range - Least Severe
→fuelSPN97-FMI16SPN 97 FMI 16: Water In Fuel Indicator - Above Normal Range - Moderately Severe
→fuelSPN97-FMI17SPN 97 FMI 17: Water In Fuel Indicator - Below Normal Range - Least Severe
→fuelSPN97-FMI18SPN 97 FMI 18: Water In Fuel Indicator - Below Normal Range - Moderately Severe
→fuelSPN97-FMI19SPN 97 FMI 19: Water In Fuel Indicator - Received Network Data In Error
→fuelSPN97-FMI31SPN 97 FMI 31: Water In Fuel Indicator - Condition Exists
→lubricationSPN98-FMI0SPN 98 FMI 0: Engine Oil Level - Data Valid But Above Normal Operational Range
→lubricationSPN98-FMI1SPN 98 FMI 1: Engine Oil Level - Data Valid But Below Normal Operational Range
→lubricationSPN98-FMI2SPN 98 FMI 2: Engine Oil Level - Data Erratic, Intermittent or Incorrect
→lubricationSPN98-FMI3SPN 98 FMI 3: Engine Oil Level - Voltage Above Normal or Shorted High
→lubricationSPN98-FMI4SPN 98 FMI 4: Engine Oil Level - Voltage Below Normal or Shorted Low
→lubricationSPN98-FMI5SPN 98 FMI 5: Engine Oil Level - Current Below Normal or Open Circuit
→lubricationSPN98-FMI6SPN 98 FMI 6: Engine Oil Level - Current Above Normal or Grounded Circuit
→lubricationSPN98-FMI7SPN 98 FMI 7: Engine Oil Level - Mechanical System Not Responding Properly
→lubricationSPN98-FMI8SPN 98 FMI 8: Engine Oil Level - Abnormal Frequency, Pulse Width or Period
→lubricationSPN98-FMI9SPN 98 FMI 9: Engine Oil Level - Abnormal Update Rate
→lubricationSPN98-FMI10SPN 98 FMI 10: Engine Oil Level - Abnormal Rate of Change
→lubricationSPN98-FMI11SPN 98 FMI 11: Engine Oil Level - Root Cause Not Known
→lubricationSPN98-FMI12SPN 98 FMI 12: Engine Oil Level - Bad Intelligent Device or Component
→lubricationSPN98-FMI13SPN 98 FMI 13: Engine Oil Level - Out of Calibration
→lubricationSPN98-FMI14SPN 98 FMI 14: Engine Oil Level - Special Instructions
→lubricationSPN98-FMI15SPN 98 FMI 15: Engine Oil Level - Above Normal Range - Least Severe
→lubricationSPN98-FMI16SPN 98 FMI 16: Engine Oil Level - Above Normal Range - Moderately Severe
→lubricationSPN98-FMI17SPN 98 FMI 17: Engine Oil Level - Below Normal Range - Least Severe
→lubricationSPN98-FMI18SPN 98 FMI 18: Engine Oil Level - Below Normal Range - Moderately Severe
→lubricationSPN98-FMI19SPN 98 FMI 19: Engine Oil Level - Received Network Data In Error
→lubricationSPN98-FMI31SPN 98 FMI 31: Engine Oil Level - Condition Exists
→lubricationSPN100-FMI0SPN 100 FMI 0: Engine Oil Pressure - Data Valid But Above Normal Operational Range
→lubricationSPN100-FMI1SPN 100 FMI 1: Engine Oil Pressure - Data Valid But Below Normal Operational Range
→lubricationSPN100-FMI2SPN 100 FMI 2: Engine Oil Pressure - Data Erratic, Intermittent or Incorrect
→lubricationSPN100-FMI3SPN 100 FMI 3: Engine Oil Pressure - Voltage Above Normal or Shorted High
→lubricationSPN100-FMI4SPN 100 FMI 4: Engine Oil Pressure - Voltage Below Normal or Shorted Low
→lubricationSPN100-FMI5SPN 100 FMI 5: Engine Oil Pressure - Current Below Normal or Open Circuit
→lubricationSPN100-FMI6SPN 100 FMI 6: Engine Oil Pressure - Current Above Normal or Grounded Circuit
→lubricationSPN100-FMI7SPN 100 FMI 7: Engine Oil Pressure - Mechanical System Not Responding Properly
→lubricationSPN100-FMI8SPN 100 FMI 8: Engine Oil Pressure - Abnormal Frequency, Pulse Width or Period
→lubricationSPN100-FMI9SPN 100 FMI 9: Engine Oil Pressure - Abnormal Update Rate
→lubricationSPN100-FMI10SPN 100 FMI 10: Engine Oil Pressure - Abnormal Rate of Change
→lubricationSPN100-FMI11SPN 100 FMI 11: Engine Oil Pressure - Root Cause Not Known
→lubricationSPN100-FMI12SPN 100 FMI 12: Engine Oil Pressure - Bad Intelligent Device or Component
→lubricationSPN100-FMI13SPN 100 FMI 13: Engine Oil Pressure - Out of Calibration
→lubricationSPN100-FMI14SPN 100 FMI 14: Engine Oil Pressure - Special Instructions
→lubricationSPN100-FMI15SPN 100 FMI 15: Engine Oil Pressure - Above Normal Range - Least Severe
→lubricationSPN100-FMI16SPN 100 FMI 16: Engine Oil Pressure - Above Normal Range - Moderately Severe
→lubricationSPN100-FMI17SPN 100 FMI 17: Engine Oil Pressure - Below Normal Range - Least Severe
→lubricationSPN100-FMI18SPN 100 FMI 18: Engine Oil Pressure - Below Normal Range - Moderately Severe
→lubricationSPN100-FMI19SPN 100 FMI 19: Engine Oil Pressure - Received Network Data In Error
→lubricationSPN100-FMI31SPN 100 FMI 31: Engine Oil Pressure - Condition Exists
→boostSPN102-FMI0SPN 102 FMI 0: Intake Manifold Pressure - Data Valid But Above Normal Operational Range
→boostSPN102-FMI1SPN 102 FMI 1: Intake Manifold Pressure - Data Valid But Below Normal Operational Range
→boostSPN102-FMI2SPN 102 FMI 2: Intake Manifold Pressure - Data Erratic, Intermittent or Incorrect
→boostSPN102-FMI3SPN 102 FMI 3: Intake Manifold Pressure - Voltage Above Normal or Shorted High
→boostSPN102-FMI4SPN 102 FMI 4: Intake Manifold Pressure - Voltage Below Normal or Shorted Low
→boostSPN102-FMI5SPN 102 FMI 5: Intake Manifold Pressure - Current Below Normal or Open Circuit
→boostSPN102-FMI6SPN 102 FMI 6: Intake Manifold Pressure - Current Above Normal or Grounded Circuit
→boostSPN102-FMI7SPN 102 FMI 7: Intake Manifold Pressure - Mechanical System Not Responding Properly
→boostSPN102-FMI8SPN 102 FMI 8: Intake Manifold Pressure - Abnormal Frequency, Pulse Width or Period
→boostSPN102-FMI9SPN 102 FMI 9: Intake Manifold Pressure - Abnormal Update Rate
→boostSPN102-FMI10SPN 102 FMI 10: Intake Manifold Pressure - Abnormal Rate of Change
→boostSPN102-FMI11SPN 102 FMI 11: Intake Manifold Pressure - Root Cause Not Known
→boostSPN102-FMI12SPN 102 FMI 12: Intake Manifold Pressure - Bad Intelligent Device or Component
→boostSPN102-FMI13SPN 102 FMI 13: Intake Manifold Pressure - Out of Calibration
→boostSPN102-FMI14SPN 102 FMI 14: Intake Manifold Pressure - Special Instructions
→boostSPN102-FMI15SPN 102 FMI 15: Intake Manifold Pressure - Above Normal Range - Least Severe
→boostSPN102-FMI16SPN 102 FMI 16: Intake Manifold Pressure - Above Normal Range - Moderately Severe
→boostSPN102-FMI17SPN 102 FMI 17: Intake Manifold Pressure - Below Normal Range - Least Severe
→boostSPN102-FMI18SPN 102 FMI 18: Intake Manifold Pressure - Below Normal Range - Moderately Severe
→boostSPN102-FMI19SPN 102 FMI 19: Intake Manifold Pressure - Received Network Data In Error
→boostSPN102-FMI31SPN 102 FMI 31: Intake Manifold Pressure - Condition Exists
→airSPN105-FMI0SPN 105 FMI 0: Intake Manifold Temperature - Data Valid But Above Normal Operational Range
→airSPN105-FMI1SPN 105 FMI 1: Intake Manifold Temperature - Data Valid But Below Normal Operational Range
→airSPN105-FMI2SPN 105 FMI 2: Intake Manifold Temperature - Data Erratic, Intermittent or Incorrect
→airSPN105-FMI3SPN 105 FMI 3: Intake Manifold Temperature - Voltage Above Normal or Shorted High
→airSPN105-FMI4SPN 105 FMI 4: Intake Manifold Temperature - Voltage Below Normal or Shorted Low
→airSPN105-FMI5SPN 105 FMI 5: Intake Manifold Temperature - Current Below Normal or Open Circuit
→airSPN105-FMI6SPN 105 FMI 6: Intake Manifold Temperature - Current Above Normal or Grounded Circuit
→airSPN105-FMI7SPN 105 FMI 7: Intake Manifold Temperature - Mechanical System Not Responding Properly
→airSPN105-FMI8SPN 105 FMI 8: Intake Manifold Temperature - Abnormal Frequency, Pulse Width or Period
→airSPN105-FMI9SPN 105 FMI 9: Intake Manifold Temperature - Abnormal Update Rate
→airSPN105-FMI10SPN 105 FMI 10: Intake Manifold Temperature - Abnormal Rate of Change
→airSPN105-FMI11SPN 105 FMI 11: Intake Manifold Temperature - Root Cause Not Known
→airSPN105-FMI12SPN 105 FMI 12: Intake Manifold Temperature - Bad Intelligent Device or Component
→airSPN105-FMI13SPN 105 FMI 13: Intake Manifold Temperature - Out of Calibration
→airSPN105-FMI14SPN 105 FMI 14: Intake Manifold Temperature - Special Instructions
→airSPN105-FMI15SPN 105 FMI 15: Intake Manifold Temperature - Above Normal Range - Least Severe
→airSPN105-FMI16SPN 105 FMI 16: Intake Manifold Temperature - Above Normal Range - Moderately Severe
→airSPN105-FMI17SPN 105 FMI 17: Intake Manifold Temperature - Below Normal Range - Least Severe
→airSPN105-FMI18SPN 105 FMI 18: Intake Manifold Temperature - Below Normal Range - Moderately Severe
→airSPN105-FMI19SPN 105 FMI 19: Intake Manifold Temperature - Received Network Data In Error
→airSPN105-FMI31SPN 105 FMI 31: Intake Manifold Temperature - Condition Exists
→coolingSPN110-FMI0SPN 110 FMI 0: Engine Coolant Temperature - Data Valid But Above Normal Operational Range
→coolingSPN110-FMI1SPN 110 FMI 1: Engine Coolant Temperature - Data Valid But Below Normal Operational Range
→coolingSPN110-FMI2SPN 110 FMI 2: Engine Coolant Temperature - Data Erratic, Intermittent or Incorrect
→coolingSPN110-FMI3SPN 110 FMI 3: Engine Coolant Temperature - Voltage Above Normal or Shorted High
→coolingSPN110-FMI4SPN 110 FMI 4: Engine Coolant Temperature - Voltage Below Normal or Shorted Low
→coolingSPN110-FMI5SPN 110 FMI 5: Engine Coolant Temperature - Current Below Normal or Open Circuit
→coolingSPN110-FMI6SPN 110 FMI 6: Engine Coolant Temperature - Current Above Normal or Grounded Circuit
→coolingSPN110-FMI7SPN 110 FMI 7: Engine Coolant Temperature - Mechanical System Not Responding Properly
→coolingSPN110-FMI8SPN 110 FMI 8: Engine Coolant Temperature - Abnormal Frequency, Pulse Width or Period
→coolingSPN110-FMI9SPN 110 FMI 9: Engine Coolant Temperature - Abnormal Update Rate
→coolingSPN110-FMI10SPN 110 FMI 10: Engine Coolant Temperature - Abnormal Rate of Change
→coolingSPN110-FMI11SPN 110 FMI 11: Engine Coolant Temperature - Root Cause Not Known
→coolingSPN110-FMI12SPN 110 FMI 12: Engine Coolant Temperature - Bad Intelligent Device or Component
→coolingSPN110-FMI13SPN 110 FMI 13: Engine Coolant Temperature - Out of Calibration
→coolingSPN110-FMI14SPN 110 FMI 14: Engine Coolant Temperature - Special Instructions
→coolingSPN110-FMI15SPN 110 FMI 15: Engine Coolant Temperature - Above Normal Range - Least Severe
→coolingSPN110-FMI16SPN 110 FMI 16: Engine Coolant Temperature - Above Normal Range - Moderately Severe
→coolingSPN110-FMI17SPN 110 FMI 17: Engine Coolant Temperature - Below Normal Range - Least Severe
→coolingSPN110-FMI18SPN 110 FMI 18: Engine Coolant Temperature - Below Normal Range - Moderately Severe
→coolingSPN110-FMI19SPN 110 FMI 19: Engine Coolant Temperature - Received Network Data In Error
→coolingSPN110-FMI31SPN 110 FMI 31: Engine Coolant Temperature - Condition Exists
→coolingSPN111-FMI0SPN 111 FMI 0: Coolant Level - Data Valid But Above Normal Operational Range
→coolingSPN111-FMI1SPN 111 FMI 1: Coolant Level - Data Valid But Below Normal Operational Range
→coolingSPN111-FMI2SPN 111 FMI 2: Coolant Level - Data Erratic, Intermittent or Incorrect
→coolingSPN111-FMI3SPN 111 FMI 3: Coolant Level - Voltage Above Normal or Shorted High
→coolingSPN111-FMI4SPN 111 FMI 4: Coolant Level - Voltage Below Normal or Shorted Low
→coolingSPN111-FMI5SPN 111 FMI 5: Coolant Level - Current Below Normal or Open Circuit
→coolingSPN111-FMI6SPN 111 FMI 6: Coolant Level - Current Above Normal or Grounded Circuit
→coolingSPN111-FMI7SPN 111 FMI 7: Coolant Level - Mechanical System Not Responding Properly
→coolingSPN111-FMI8SPN 111 FMI 8: Coolant Level - Abnormal Frequency, Pulse Width or Period
→coolingSPN111-FMI9SPN 111 FMI 9: Coolant Level - Abnormal Update Rate
→coolingSPN111-FMI10SPN 111 FMI 10: Coolant Level - Abnormal Rate of Change
→coolingSPN111-FMI11SPN 111 FMI 11: Coolant Level - Root Cause Not Known
→coolingSPN111-FMI12SPN 111 FMI 12: Coolant Level - Bad Intelligent Device or Component
→coolingSPN111-FMI13SPN 111 FMI 13: Coolant Level - Out of Calibration
→coolingSPN111-FMI14SPN 111 FMI 14: Coolant Level - Special Instructions
→coolingSPN111-FMI15SPN 111 FMI 15: Coolant Level - Above Normal Range - Least Severe
→coolingSPN111-FMI16SPN 111 FMI 16: Coolant Level - Above Normal Range - Moderately Severe
→coolingSPN111-FMI17SPN 111 FMI 17: Coolant Level - Below Normal Range - Least Severe
→coolingSPN111-FMI18SPN 111 FMI 18: Coolant Level - Below Normal Range - Moderately Severe
→coolingSPN111-FMI19SPN 111 FMI 19: Coolant Level - Received Network Data In Error
→coolingSPN111-FMI31SPN 111 FMI 31: Coolant Level - Condition Exists
→fuelSPN157-FMI0SPN 157 FMI 0: Fuel Rail Pressure - Data Valid But Above Normal Operational Range
→fuelSPN157-FMI1SPN 157 FMI 1: Fuel Rail Pressure - Data Valid But Below Normal Operational Range
→fuelSPN157-FMI2SPN 157 FMI 2: Fuel Rail Pressure - Data Erratic, Intermittent or Incorrect
→fuelSPN157-FMI3SPN 157 FMI 3: Fuel Rail Pressure - Voltage Above Normal or Shorted High
→fuelSPN157-FMI4SPN 157 FMI 4: Fuel Rail Pressure - Voltage Below Normal or Shorted Low
→fuelSPN157-FMI5SPN 157 FMI 5: Fuel Rail Pressure - Current Below Normal or Open Circuit
→fuelSPN157-FMI6SPN 157 FMI 6: Fuel Rail Pressure - Current Above Normal or Grounded Circuit
→fuelSPN157-FMI7SPN 157 FMI 7: Fuel Rail Pressure - Mechanical System Not Responding Properly
→fuelSPN157-FMI8SPN 157 FMI 8: Fuel Rail Pressure - Abnormal Frequency, Pulse Width or Period
→fuelSPN157-FMI9SPN 157 FMI 9: Fuel Rail Pressure - Abnormal Update Rate
→fuelSPN157-FMI10SPN 157 FMI 10: Fuel Rail Pressure - Abnormal Rate of Change
→fuelSPN157-FMI11SPN 157 FMI 11: Fuel Rail Pressure - Root Cause Not Known
→fuelSPN157-FMI12SPN 157 FMI 12: Fuel Rail Pressure - Bad Intelligent Device or Component
→fuelSPN157-FMI13SPN 157 FMI 13: Fuel Rail Pressure - Out of Calibration
→fuelSPN157-FMI14SPN 157 FMI 14: Fuel Rail Pressure - Special Instructions
→fuelSPN157-FMI15SPN 157 FMI 15: Fuel Rail Pressure - Above Normal Range - Least Severe
→fuelSPN157-FMI16SPN 157 FMI 16: Fuel Rail Pressure - Above Normal Range - Moderately Severe
→fuelSPN157-FMI17SPN 157 FMI 17: Fuel Rail Pressure - Below Normal Range - Least Severe
→fuelSPN157-FMI18SPN 157 FMI 18: Fuel Rail Pressure - Below Normal Range - Moderately Severe
→fuelSPN157-FMI19SPN 157 FMI 19: Fuel Rail Pressure - Received Network Data In Error
→fuelSPN157-FMI31SPN 157 FMI 31: Fuel Rail Pressure - Condition Exists
→powerSPN168-FMI0SPN 168 FMI 0: Battery Potential - Data Valid But Above Normal Operational Range
→powerSPN168-FMI1SPN 168 FMI 1: Battery Potential - Data Valid But Below Normal Operational Range
→powerSPN168-FMI2SPN 168 FMI 2: Battery Potential - Data Erratic, Intermittent or Incorrect
→powerSPN168-FMI3SPN 168 FMI 3: Battery Potential - Voltage Above Normal or Shorted High
→powerSPN168-FMI4SPN 168 FMI 4: Battery Potential - Voltage Below Normal or Shorted Low
→powerSPN168-FMI5SPN 168 FMI 5: Battery Potential - Current Below Normal or Open Circuit
→powerSPN168-FMI6SPN 168 FMI 6: Battery Potential - Current Above Normal or Grounded Circuit
→powerSPN168-FMI7SPN 168 FMI 7: Battery Potential - Mechanical System Not Responding Properly
→powerSPN168-FMI8SPN 168 FMI 8: Battery Potential - Abnormal Frequency, Pulse Width or Period
→powerSPN168-FMI9SPN 168 FMI 9: Battery Potential - Abnormal Update Rate
→powerSPN168-FMI10SPN 168 FMI 10: Battery Potential - Abnormal Rate of Change
→powerSPN168-FMI11SPN 168 FMI 11: Battery Potential - Root Cause Not Known
→powerSPN168-FMI12SPN 168 FMI 12: Battery Potential - Bad Intelligent Device or Component
→powerSPN168-FMI13SPN 168 FMI 13: Battery Potential - Out of Calibration
→powerSPN168-FMI14SPN 168 FMI 14: Battery Potential - Special Instructions
→powerSPN168-FMI15SPN 168 FMI 15: Battery Potential - Above Normal Range - Least Severe
→powerSPN168-FMI16SPN 168 FMI 16: Battery Potential - Above Normal Range - Moderately Severe
→powerSPN168-FMI17SPN 168 FMI 17: Battery Potential - Below Normal Range - Least Severe
→powerSPN168-FMI18SPN 168 FMI 18: Battery Potential - Below Normal Range - Moderately Severe
→powerSPN168-FMI19SPN 168 FMI 19: Battery Potential - Received Network Data In Error
→powerSPN168-FMI31SPN 168 FMI 31: Battery Potential - Condition Exists
→airSPN171-FMI0SPN 171 FMI 0: Ambient Air Temperature - Data Valid But Above Normal Operational Range
→airSPN171-FMI1SPN 171 FMI 1: Ambient Air Temperature - Data Valid But Below Normal Operational Range
→airSPN171-FMI2SPN 171 FMI 2: Ambient Air Temperature - Data Erratic, Intermittent or Incorrect
→airSPN171-FMI3SPN 171 FMI 3: Ambient Air Temperature - Voltage Above Normal or Shorted High
→airSPN171-FMI4SPN 171 FMI 4: Ambient Air Temperature - Voltage Below Normal or Shorted Low
→airSPN171-FMI5SPN 171 FMI 5: Ambient Air Temperature - Current Below Normal or Open Circuit
→airSPN171-FMI6SPN 171 FMI 6: Ambient Air Temperature - Current Above Normal or Grounded Circuit
→airSPN171-FMI7SPN 171 FMI 7: Ambient Air Temperature - Mechanical System Not Responding Properly
→airSPN171-FMI8SPN 171 FMI 8: Ambient Air Temperature - Abnormal Frequency, Pulse Width or Period
→airSPN171-FMI9SPN 171 FMI 9: Ambient Air Temperature - Abnormal Update Rate
→airSPN171-FMI10SPN 171 FMI 10: Ambient Air Temperature - Abnormal Rate of Change
→airSPN171-FMI11SPN 171 FMI 11: Ambient Air Temperature - Root Cause Not Known
→airSPN171-FMI12SPN 171 FMI 12: Ambient Air Temperature - Bad Intelligent Device or Component
→airSPN171-FMI13SPN 171 FMI 13: Ambient Air Temperature - Out of Calibration
→airSPN171-FMI14SPN 171 FMI 14: Ambient Air Temperature - Special Instructions
→airSPN171-FMI15SPN 171 FMI 15: Ambient Air Temperature - Above Normal Range - Least Severe
→airSPN171-FMI16SPN 171 FMI 16: Ambient Air Temperature - Above Normal Range - Moderately Severe
→airSPN171-FMI17SPN 171 FMI 17: Ambient Air Temperature - Below Normal Range - Least Severe
→airSPN171-FMI18SPN 171 FMI 18: Ambient Air Temperature - Below Normal Range - Moderately Severe
→airSPN171-FMI19SPN 171 FMI 19: Ambient Air Temperature - Received Network Data In Error
→airSPN171-FMI31SPN 171 FMI 31: Ambient Air Temperature - Condition Exists
→lubricationSPN175-FMI0SPN 175 FMI 0: Engine Oil Temperature - Data Valid But Above Normal Operational Range
→lubricationSPN175-FMI1SPN 175 FMI 1: Engine Oil Temperature - Data Valid But Below Normal Operational Range
→lubricationSPN175-FMI2SPN 175 FMI 2: Engine Oil Temperature - Data Erratic, Intermittent or Incorrect
→lubricationSPN175-FMI3SPN 175 FMI 3: Engine Oil Temperature - Voltage Above Normal or Shorted High
→lubricationSPN175-FMI4SPN 175 FMI 4: Engine Oil Temperature - Voltage Below Normal or Shorted Low
→lubricationSPN175-FMI5SPN 175 FMI 5: Engine Oil Temperature - Current Below Normal or Open Circuit
→lubricationSPN175-FMI6SPN 175 FMI 6: Engine Oil Temperature - Current Above Normal or Grounded Circuit
→lubricationSPN175-FMI7SPN 175 FMI 7: Engine Oil Temperature - Mechanical System Not Responding Properly
→lubricationSPN175-FMI8SPN 175 FMI 8: Engine Oil Temperature - Abnormal Frequency, Pulse Width or Period
→lubricationSPN175-FMI9SPN 175 FMI 9: Engine Oil Temperature - Abnormal Update Rate
→lubricationSPN175-FMI10SPN 175 FMI 10: Engine Oil Temperature - Abnormal Rate of Change
→lubricationSPN175-FMI11SPN 175 FMI 11: Engine Oil Temperature - Root Cause Not Known
→lubricationSPN175-FMI12SPN 175 FMI 12: Engine Oil Temperature - Bad Intelligent Device or Component
→lubricationSPN175-FMI13SPN 175 FMI 13: Engine Oil Temperature - Out of Calibration
→lubricationSPN175-FMI14SPN 175 FMI 14: Engine Oil Temperature - Special Instructions
→lubricationSPN175-FMI15SPN 175 FMI 15: Engine Oil Temperature - Above Normal Range - Least Severe
→lubricationSPN175-FMI16SPN 175 FMI 16: Engine Oil Temperature - Above Normal Range - Moderately Severe
→lubricationSPN175-FMI17SPN 175 FMI 17: Engine Oil Temperature - Below Normal Range - Least Severe
→lubricationSPN175-FMI18SPN 175 FMI 18: Engine Oil Temperature - Below Normal Range - Moderately Severe
→lubricationSPN175-FMI19SPN 175 FMI 19: Engine Oil Temperature - Received Network Data In Error
→lubricationSPN175-FMI31SPN 175 FMI 31: Engine Oil Temperature - Condition Exists
→engine_controlSPN190-FMI0SPN 190 FMI 0: Engine Speed - Data Valid But Above Normal Operational Range
→engine_controlSPN190-FMI1SPN 190 FMI 1: Engine Speed - Data Valid But Below Normal Operational Range
→engine_controlSPN190-FMI2SPN 190 FMI 2: Engine Speed - Data Erratic, Intermittent or Incorrect
→engine_controlSPN190-FMI3SPN 190 FMI 3: Engine Speed - Voltage Above Normal or Shorted High
→engine_controlSPN190-FMI4SPN 190 FMI 4: Engine Speed - Voltage Below Normal or Shorted Low
→engine_controlSPN190-FMI5SPN 190 FMI 5: Engine Speed - Current Below Normal or Open Circuit
→engine_controlSPN190-FMI6SPN 190 FMI 6: Engine Speed - Current Above Normal or Grounded Circuit
→engine_controlSPN190-FMI7SPN 190 FMI 7: Engine Speed - Mechanical System Not Responding Properly
→engine_controlSPN190-FMI8SPN 190 FMI 8: Engine Speed - Abnormal Frequency, Pulse Width or Period
→engine_controlSPN190-FMI9SPN 190 FMI 9: Engine Speed - Abnormal Update Rate
→engine_controlSPN190-FMI10SPN 190 FMI 10: Engine Speed - Abnormal Rate of Change
→engine_controlSPN190-FMI11SPN 190 FMI 11: Engine Speed - Root Cause Not Known
→engine_controlSPN190-FMI12SPN 190 FMI 12: Engine Speed - Bad Intelligent Device or Component
→engine_controlSPN190-FMI13SPN 190 FMI 13: Engine Speed - Out of Calibration
→engine_controlSPN190-FMI14SPN 190 FMI 14: Engine Speed - Special Instructions
→engine_controlSPN190-FMI15SPN 190 FMI 15: Engine Speed - Above Normal Range - Least Severe
→engine_controlSPN190-FMI16SPN 190 FMI 16: Engine Speed - Above Normal Range - Moderately Severe
→engine_controlSPN190-FMI17SPN 190 FMI 17: Engine Speed - Below Normal Range - Least Severe
→engine_controlSPN190-FMI18SPN 190 FMI 18: Engine Speed - Below Normal Range - Moderately Severe
→engine_controlSPN190-FMI19SPN 190 FMI 19: Engine Speed - Received Network Data In Error
→engine_controlSPN190-FMI31SPN 190 FMI 31: Engine Speed - Condition Exists
→transmissionSPN191-FMI0SPN 191 FMI 0: Transmission Output Shaft Speed - Data Valid But Above Normal Operational Range
→transmissionSPN191-FMI1SPN 191 FMI 1: Transmission Output Shaft Speed - Data Valid But Below Normal Operational Range
→transmissionSPN191-FMI2SPN 191 FMI 2: Transmission Output Shaft Speed - Data Erratic, Intermittent or Incorrect
→transmissionSPN191-FMI3SPN 191 FMI 3: Transmission Output Shaft Speed - Voltage Above Normal or Shorted High
→transmissionSPN191-FMI4SPN 191 FMI 4: Transmission Output Shaft Speed - Voltage Below Normal or Shorted Low
→transmissionSPN191-FMI5SPN 191 FMI 5: Transmission Output Shaft Speed - Current Below Normal or Open Circuit
→transmissionSPN191-FMI6SPN 191 FMI 6: Transmission Output Shaft Speed - Current Above Normal or Grounded Circuit
→transmissionSPN191-FMI7SPN 191 FMI 7: Transmission Output Shaft Speed - Mechanical System Not Responding Properly
→transmissionSPN191-FMI8SPN 191 FMI 8: Transmission Output Shaft Speed - Abnormal Frequency, Pulse Width or Period
→transmissionSPN191-FMI9SPN 191 FMI 9: Transmission Output Shaft Speed - Abnormal Update Rate
→transmissionSPN191-FMI10SPN 191 FMI 10: Transmission Output Shaft Speed - Abnormal Rate of Change
→transmissionSPN191-FMI11SPN 191 FMI 11: Transmission Output Shaft Speed - Root Cause Not Known
→transmissionSPN191-FMI12SPN 191 FMI 12: Transmission Output Shaft Speed - Bad Intelligent Device or Component
→transmissionSPN191-FMI13SPN 191 FMI 13: Transmission Output Shaft Speed - Out of Calibration
→transmissionSPN191-FMI14SPN 191 FMI 14: Transmission Output Shaft Speed - Special Instructions
→transmissionSPN191-FMI15SPN 191 FMI 15: Transmission Output Shaft Speed - Above Normal Range - Least Severe
→transmissionSPN191-FMI16SPN 191 FMI 16: Transmission Output Shaft Speed - Above Normal Range - Moderately Severe
→transmissionSPN191-FMI17SPN 191 FMI 17: Transmission Output Shaft Speed - Below Normal Range - Least Severe
→transmissionSPN191-FMI18SPN 191 FMI 18: Transmission Output Shaft Speed - Below Normal Range - Moderately Severe
→transmissionSPN191-FMI19SPN 191 FMI 19: Transmission Output Shaft Speed - Received Network Data In Error
→transmissionSPN191-FMI31SPN 191 FMI 31: Transmission Output Shaft Speed - Condition Exists
→engine_controlSPN247-FMI0SPN 247 FMI 0: Total Engine Hours - Data Valid But Above Normal Operational Range
→engine_controlSPN247-FMI1SPN 247 FMI 1: Total Engine Hours - Data Valid But Below Normal Operational Range
→engine_controlSPN247-FMI2SPN 247 FMI 2: Total Engine Hours - Data Erratic, Intermittent or Incorrect
→engine_controlSPN247-FMI3SPN 247 FMI 3: Total Engine Hours - Voltage Above Normal or Shorted High
→engine_controlSPN247-FMI4SPN 247 FMI 4: Total Engine Hours - Voltage Below Normal or Shorted Low
→engine_controlSPN247-FMI5SPN 247 FMI 5: Total Engine Hours - Current Below Normal or Open Circuit
→engine_controlSPN247-FMI6SPN 247 FMI 6: Total Engine Hours - Current Above Normal or Grounded Circuit
→engine_controlSPN247-FMI7SPN 247 FMI 7: Total Engine Hours - Mechanical System Not Responding Properly
→engine_controlSPN247-FMI8SPN 247 FMI 8: Total Engine Hours - Abnormal Frequency, Pulse Width or Period
→engine_controlSPN247-FMI9SPN 247 FMI 9: Total Engine Hours - Abnormal Update Rate
→engine_controlSPN247-FMI10SPN 247 FMI 10: Total Engine Hours - Abnormal Rate of Change
→engine_controlSPN247-FMI11SPN 247 FMI 11: Total Engine Hours - Root Cause Not Known
→engine_controlSPN247-FMI12SPN 247 FMI 12: Total Engine Hours - Bad Intelligent Device or Component
→engine_controlSPN247-FMI13SPN 247 FMI 13: Total Engine Hours - Out of Calibration
→engine_controlSPN247-FMI14SPN 247 FMI 14: Total Engine Hours - Special Instructions
→engine_controlSPN247-FMI15SPN 247 FMI 15: Total Engine Hours - Above Normal Range - Least Severe
→engine_controlSPN247-FMI16SPN 247 FMI 16: Total Engine Hours - Above Normal Range - Moderately Severe
→engine_controlSPN247-FMI17SPN 247 FMI 17: Total Engine Hours - Below Normal Range - Least Severe
→engine_controlSPN247-FMI18SPN 247 FMI 18: Total Engine Hours - Below Normal Range - Moderately Severe
→engine_controlSPN247-FMI19SPN 247 FMI 19: Total Engine Hours - Received Network Data In Error
→engine_controlSPN247-FMI31SPN 247 FMI 31: Total Engine Hours - Condition Exists
→egrSPN411-FMI0SPN 411 FMI 0: EGR Differential Pressure - Data Valid But Above Normal Operational Range
→egrSPN411-FMI1SPN 411 FMI 1: EGR Differential Pressure - Data Valid But Below Normal Operational Range
→egrSPN411-FMI2SPN 411 FMI 2: EGR Differential Pressure - Data Erratic, Intermittent or Incorrect
→egrSPN411-FMI3SPN 411 FMI 3: EGR Differential Pressure - Voltage Above Normal or Shorted High
→egrSPN411-FMI4SPN 411 FMI 4: EGR Differential Pressure - Voltage Below Normal or Shorted Low
→egrSPN411-FMI5SPN 411 FMI 5: EGR Differential Pressure - Current Below Normal or Open Circuit
→egrSPN411-FMI6SPN 411 FMI 6: EGR Differential Pressure - Current Above Normal or Grounded Circuit
→egrSPN411-FMI7SPN 411 FMI 7: EGR Differential Pressure - Mechanical System Not Responding Properly
→egrSPN411-FMI8SPN 411 FMI 8: EGR Differential Pressure - Abnormal Frequency, Pulse Width or Period
→egrSPN411-FMI9SPN 411 FMI 9: EGR Differential Pressure - Abnormal Update Rate
→egrSPN411-FMI10SPN 411 FMI 10: EGR Differential Pressure - Abnormal Rate of Change
→egrSPN411-FMI11SPN 411 FMI 11: EGR Differential Pressure - Root Cause Not Known
→egrSPN411-FMI12SPN 411 FMI 12: EGR Differential Pressure - Bad Intelligent Device or Component
→egrSPN411-FMI13SPN 411 FMI 13: EGR Differential Pressure - Out of Calibration
→egrSPN411-FMI14SPN 411 FMI 14: EGR Differential Pressure - Special Instructions
→egrSPN411-FMI15SPN 411 FMI 15: EGR Differential Pressure - Above Normal Range - Least Severe
→egrSPN411-FMI16SPN 411 FMI 16: EGR Differential Pressure - Above Normal Range - Moderately Severe
→egrSPN411-FMI17SPN 411 FMI 17: EGR Differential Pressure - Below Normal Range - Least Severe
→egrSPN411-FMI18SPN 411 FMI 18: EGR Differential Pressure - Below Normal Range - Moderately Severe
→egrSPN411-FMI19SPN 411 FMI 19: EGR Differential Pressure - Received Network Data In Error
→egrSPN411-FMI31SPN 411 FMI 31: EGR Differential Pressure - Condition Exists
→engine_controlSPN512-FMI0SPN 512 FMI 0: Driver Demand Engine Torque - Data Valid But Above Normal Operational Range
→engine_controlSPN512-FMI1SPN 512 FMI 1: Driver Demand Engine Torque - Data Valid But Below Normal Operational Range
→engine_controlSPN512-FMI2SPN 512 FMI 2: Driver Demand Engine Torque - Data Erratic, Intermittent or Incorrect
→engine_controlSPN512-FMI3SPN 512 FMI 3: Driver Demand Engine Torque - Voltage Above Normal or Shorted High
→engine_controlSPN512-FMI4SPN 512 FMI 4: Driver Demand Engine Torque - Voltage Below Normal or Shorted Low
→engine_controlSPN512-FMI5SPN 512 FMI 5: Driver Demand Engine Torque - Current Below Normal or Open Circuit
→engine_controlSPN512-FMI6SPN 512 FMI 6: Driver Demand Engine Torque - Current Above Normal or Grounded Circuit
→engine_controlSPN512-FMI7SPN 512 FMI 7: Driver Demand Engine Torque - Mechanical System Not Responding Properly
→engine_controlSPN512-FMI8SPN 512 FMI 8: Driver Demand Engine Torque - Abnormal Frequency, Pulse Width or Period
→engine_controlSPN512-FMI9SPN 512 FMI 9: Driver Demand Engine Torque - Abnormal Update Rate
→engine_controlSPN512-FMI10SPN 512 FMI 10: Driver Demand Engine Torque - Abnormal Rate of Change
→engine_controlSPN512-FMI11SPN 512 FMI 11: Driver Demand Engine Torque - Root Cause Not Known
→engine_controlSPN512-FMI12SPN 512 FMI 12: Driver Demand Engine Torque - Bad Intelligent Device or Component
→engine_controlSPN512-FMI13SPN 512 FMI 13: Driver Demand Engine Torque - Out of Calibration
→engine_controlSPN512-FMI14SPN 512 FMI 14: Driver Demand Engine Torque - Special Instructions
→engine_controlSPN512-FMI15SPN 512 FMI 15: Driver Demand Engine Torque - Above Normal Range - Least Severe
→engine_controlSPN512-FMI16SPN 512 FMI 16: Driver Demand Engine Torque - Above Normal Range - Moderately Severe
→engine_controlSPN512-FMI17SPN 512 FMI 17: Driver Demand Engine Torque - Below Normal Range - Least Severe
→engine_controlSPN512-FMI18SPN 512 FMI 18: Driver Demand Engine Torque - Below Normal Range - Moderately Severe
→engine_controlSPN512-FMI19SPN 512 FMI 19: Driver Demand Engine Torque - Received Network Data In Error
→engine_controlSPN512-FMI31SPN 512 FMI 31: Driver Demand Engine Torque - Condition Exists
→engine_controlSPN513-FMI0SPN 513 FMI 0: Actual Engine Torque - Data Valid But Above Normal Operational Range
→engine_controlSPN513-FMI1SPN 513 FMI 1: Actual Engine Torque - Data Valid But Below Normal Operational Range
→engine_controlSPN513-FMI2SPN 513 FMI 2: Actual Engine Torque - Data Erratic, Intermittent or Incorrect
→engine_controlSPN513-FMI3SPN 513 FMI 3: Actual Engine Torque - Voltage Above Normal or Shorted High
→engine_controlSPN513-FMI4SPN 513 FMI 4: Actual Engine Torque - Voltage Below Normal or Shorted Low
→engine_controlSPN513-FMI5SPN 513 FMI 5: Actual Engine Torque - Current Below Normal or Open Circuit
→engine_controlSPN513-FMI6SPN 513 FMI 6: Actual Engine Torque - Current Above Normal or Grounded Circuit
→engine_controlSPN513-FMI7SPN 513 FMI 7: Actual Engine Torque - Mechanical System Not Responding Properly
→engine_controlSPN513-FMI8SPN 513 FMI 8: Actual Engine Torque - Abnormal Frequency, Pulse Width or Period
→engine_controlSPN513-FMI9SPN 513 FMI 9: Actual Engine Torque - Abnormal Update Rate
→engine_controlSPN513-FMI10SPN 513 FMI 10: Actual Engine Torque - Abnormal Rate of Change
→engine_controlSPN513-FMI11SPN 513 FMI 11: Actual Engine Torque - Root Cause Not Known
→engine_controlSPN513-FMI12SPN 513 FMI 12: Actual Engine Torque - Bad Intelligent Device or Component
→engine_controlSPN513-FMI13SPN 513 FMI 13: Actual Engine Torque - Out of Calibration
→engine_controlSPN513-FMI14SPN 513 FMI 14: Actual Engine Torque - Special Instructions
→engine_controlSPN513-FMI15SPN 513 FMI 15: Actual Engine Torque - Above Normal Range - Least Severe
→engine_controlSPN513-FMI16SPN 513 FMI 16: Actual Engine Torque - Above Normal Range - Moderately Severe
→engine_controlSPN513-FMI17SPN 513 FMI 17: Actual Engine Torque - Below Normal Range - Least Severe
→engine_controlSPN513-FMI18SPN 513 FMI 18: Actual Engine Torque - Below Normal Range - Moderately Severe
→engine_controlSPN513-FMI19SPN 513 FMI 19: Actual Engine Torque - Received Network Data In Error
→engine_controlSPN513-FMI31SPN 513 FMI 31: Actual Engine Torque - Condition Exists
→transmissionSPN520-FMI0SPN 520 FMI 0: Transmission Current Gear - Data Valid But Above Normal Operational Range
→transmissionSPN520-FMI1SPN 520 FMI 1: Transmission Current Gear - Data Valid But Below Normal Operational Range
→transmissionSPN520-FMI2SPN 520 FMI 2: Transmission Current Gear - Data Erratic, Intermittent or Incorrect
→transmissionSPN520-FMI3SPN 520 FMI 3: Transmission Current Gear - Voltage Above Normal or Shorted High
→transmissionSPN520-FMI4SPN 520 FMI 4: Transmission Current Gear - Voltage Below Normal or Shorted Low
→transmissionSPN520-FMI5SPN 520 FMI 5: Transmission Current Gear - Current Below Normal or Open Circuit
→transmissionSPN520-FMI6SPN 520 FMI 6: Transmission Current Gear - Current Above Normal or Grounded Circuit
→transmissionSPN520-FMI7SPN 520 FMI 7: Transmission Current Gear - Mechanical System Not Responding Properly
→transmissionSPN520-FMI8SPN 520 FMI 8: Transmission Current Gear - Abnormal Frequency, Pulse Width or Period
→transmissionSPN520-FMI9SPN 520 FMI 9: Transmission Current Gear - Abnormal Update Rate
→transmissionSPN520-FMI10SPN 520 FMI 10: Transmission Current Gear - Abnormal Rate of Change
→transmissionSPN520-FMI11SPN 520 FMI 11: Transmission Current Gear - Root Cause Not Known
→transmissionSPN520-FMI12SPN 520 FMI 12: Transmission Current Gear - Bad Intelligent Device or Component
→transmissionSPN520-FMI13SPN 520 FMI 13: Transmission Current Gear - Out of Calibration
→transmissionSPN520-FMI14SPN 520 FMI 14: Transmission Current Gear - Special Instructions
→transmissionSPN520-FMI15SPN 520 FMI 15: Transmission Current Gear - Above Normal Range - Least Severe
→transmissionSPN520-FMI16SPN 520 FMI 16: Transmission Current Gear - Above Normal Range - Moderately Severe
→transmissionSPN520-FMI17SPN 520 FMI 17: Transmission Current Gear - Below Normal Range - Least Severe
→transmissionSPN520-FMI18SPN 520 FMI 18: Transmission Current Gear - Below Normal Range - Moderately Severe
→transmissionSPN520-FMI19SPN 520 FMI 19: Transmission Current Gear - Received Network Data In Error
→transmissionSPN520-FMI31SPN 520 FMI 31: Transmission Current Gear - Condition Exists
→transmissionSPN523-FMI0SPN 523 FMI 0: Transmission Selected Gear - Data Valid But Above Normal Operational Range
→transmissionSPN523-FMI1SPN 523 FMI 1: Transmission Selected Gear - Data Valid But Below Normal Operational Range
→transmissionSPN523-FMI2SPN 523 FMI 2: Transmission Selected Gear - Data Erratic, Intermittent or Incorrect
→transmissionSPN523-FMI3SPN 523 FMI 3: Transmission Selected Gear - Voltage Above Normal or Shorted High
→transmissionSPN523-FMI4SPN 523 FMI 4: Transmission Selected Gear - Voltage Below Normal or Shorted Low
→transmissionSPN523-FMI5SPN 523 FMI 5: Transmission Selected Gear - Current Below Normal or Open Circuit
→transmissionSPN523-FMI6SPN 523 FMI 6: Transmission Selected Gear - Current Above Normal or Grounded Circuit
→transmissionSPN523-FMI7SPN 523 FMI 7: Transmission Selected Gear - Mechanical System Not Responding Properly
→transmissionSPN523-FMI8SPN 523 FMI 8: Transmission Selected Gear - Abnormal Frequency, Pulse Width or Period
→transmissionSPN523-FMI9SPN 523 FMI 9: Transmission Selected Gear - Abnormal Update Rate
→transmissionSPN523-FMI10SPN 523 FMI 10: Transmission Selected Gear - Abnormal Rate of Change
→transmissionSPN523-FMI11SPN 523 FMI 11: Transmission Selected Gear - Root Cause Not Known
→transmissionSPN523-FMI12SPN 523 FMI 12: Transmission Selected Gear - Bad Intelligent Device or Component
→transmissionSPN523-FMI13SPN 523 FMI 13: Transmission Selected Gear - Out of Calibration
→transmissionSPN523-FMI14SPN 523 FMI 14: Transmission Selected Gear - Special Instructions
→transmissionSPN523-FMI15SPN 523 FMI 15: Transmission Selected Gear - Above Normal Range - Least Severe
→transmissionSPN523-FMI16SPN 523 FMI 16: Transmission Selected Gear - Above Normal Range - Moderately Severe
→transmissionSPN523-FMI17SPN 523 FMI 17: Transmission Selected Gear - Below Normal Range - Least Severe
→transmissionSPN523-FMI18SPN 523 FMI 18: Transmission Selected Gear - Below Normal Range - Moderately Severe
→transmissionSPN523-FMI19SPN 523 FMI 19: Transmission Selected Gear - Received Network Data In Error
→transmissionSPN523-FMI31SPN 523 FMI 31: Transmission Selected Gear - Condition Exists
→networkSPN639-FMI0SPN 639 FMI 0: J1939 Network Error - Data Valid But Above Normal Operational Range
→networkSPN639-FMI1SPN 639 FMI 1: J1939 Network Error - Data Valid But Below Normal Operational Range
→networkSPN639-FMI2SPN 639 FMI 2: J1939 Network Error - Data Erratic, Intermittent or Incorrect
→networkSPN639-FMI3SPN 639 FMI 3: J1939 Network Error - Voltage Above Normal or Shorted High
→networkSPN639-FMI4SPN 639 FMI 4: J1939 Network Error - Voltage Below Normal or Shorted Low
→networkSPN639-FMI5SPN 639 FMI 5: J1939 Network Error - Current Below Normal or Open Circuit
→networkSPN639-FMI6SPN 639 FMI 6: J1939 Network Error - Current Above Normal or Grounded Circuit
→networkSPN639-FMI7SPN 639 FMI 7: J1939 Network Error - Mechanical System Not Responding Properly
→networkSPN639-FMI8SPN 639 FMI 8: J1939 Network Error - Abnormal Frequency, Pulse Width or Period
→networkSPN639-FMI9SPN 639 FMI 9: J1939 Network Error - Abnormal Update Rate
→networkSPN639-FMI10SPN 639 FMI 10: J1939 Network Error - Abnormal Rate of Change
→networkSPN639-FMI11SPN 639 FMI 11: J1939 Network Error - Root Cause Not Known
→networkSPN639-FMI12SPN 639 FMI 12: J1939 Network Error - Bad Intelligent Device or Component
→networkSPN639-FMI13SPN 639 FMI 13: J1939 Network Error - Out of Calibration
→networkSPN639-FMI14SPN 639 FMI 14: J1939 Network Error - Special Instructions
→networkSPN639-FMI15SPN 639 FMI 15: J1939 Network Error - Above Normal Range - Least Severe
→networkSPN639-FMI16SPN 639 FMI 16: J1939 Network Error - Above Normal Range - Moderately Severe
→networkSPN639-FMI17SPN 639 FMI 17: J1939 Network Error - Below Normal Range - Least Severe
→networkSPN639-FMI18SPN 639 FMI 18: J1939 Network Error - Below Normal Range - Moderately Severe
→networkSPN639-FMI19SPN 639 FMI 19: J1939 Network Error - Received Network Data In Error
→networkSPN639-FMI31SPN 639 FMI 31: J1939 Network Error - Condition Exists
→injectorSPN651-FMI0SPN 651 FMI 0: Cylinder 1 Injector - Data Valid But Above Normal Operational Range
→injectorSPN651-FMI1SPN 651 FMI 1: Cylinder 1 Injector - Data Valid But Below Normal Operational Range
→injectorSPN651-FMI2SPN 651 FMI 2: Cylinder 1 Injector - Data Erratic, Intermittent or Incorrect
→injectorSPN651-FMI3SPN 651 FMI 3: Cylinder 1 Injector - Voltage Above Normal or Shorted High
→injectorSPN651-FMI4SPN 651 FMI 4: Cylinder 1 Injector - Voltage Below Normal or Shorted Low
→injectorSPN651-FMI5SPN 651 FMI 5: Cylinder 1 Injector - Current Below Normal or Open Circuit
→injectorSPN651-FMI6SPN 651 FMI 6: Cylinder 1 Injector - Current Above Normal or Grounded Circuit
→injectorSPN651-FMI7SPN 651 FMI 7: Cylinder 1 Injector - Mechanical System Not Responding Properly
→injectorSPN651-FMI8SPN 651 FMI 8: Cylinder 1 Injector - Abnormal Frequency, Pulse Width or Period
→injectorSPN651-FMI9SPN 651 FMI 9: Cylinder 1 Injector - Abnormal Update Rate
→injectorSPN651-FMI10SPN 651 FMI 10: Cylinder 1 Injector - Abnormal Rate of Change
→injectorSPN651-FMI11SPN 651 FMI 11: Cylinder 1 Injector - Root Cause Not Known
→injectorSPN651-FMI12SPN 651 FMI 12: Cylinder 1 Injector - Bad Intelligent Device or Component
→injectorSPN651-FMI13SPN 651 FMI 13: Cylinder 1 Injector - Out of Calibration
→injectorSPN651-FMI14SPN 651 FMI 14: Cylinder 1 Injector - Special Instructions
→injectorSPN651-FMI15SPN 651 FMI 15: Cylinder 1 Injector - Above Normal Range - Least Severe
→injectorSPN651-FMI16SPN 651 FMI 16: Cylinder 1 Injector - Above Normal Range - Moderately Severe
→injectorSPN651-FMI17SPN 651 FMI 17: Cylinder 1 Injector - Below Normal Range - Least Severe
→injectorSPN651-FMI18SPN 651 FMI 18: Cylinder 1 Injector - Below Normal Range - Moderately Severe
→injectorSPN651-FMI19SPN 651 FMI 19: Cylinder 1 Injector - Received Network Data In Error
→injectorSPN651-FMI31SPN 651 FMI 31: Cylinder 1 Injector - Condition Exists
→injectorSPN652-FMI0SPN 652 FMI 0: Cylinder 2 Injector - Data Valid But Above Normal Operational Range
→injectorSPN652-FMI1SPN 652 FMI 1: Cylinder 2 Injector - Data Valid But Below Normal Operational Range
→injectorSPN652-FMI2SPN 652 FMI 2: Cylinder 2 Injector - Data Erratic, Intermittent or Incorrect
→injectorSPN652-FMI3SPN 652 FMI 3: Cylinder 2 Injector - Voltage Above Normal or Shorted High
→injectorSPN652-FMI4SPN 652 FMI 4: Cylinder 2 Injector - Voltage Below Normal or Shorted Low
→injectorSPN652-FMI5SPN 652 FMI 5: Cylinder 2 Injector - Current Below Normal or Open Circuit
→injectorSPN652-FMI6SPN 652 FMI 6: Cylinder 2 Injector - Current Above Normal or Grounded Circuit
→injectorSPN652-FMI7SPN 652 FMI 7: Cylinder 2 Injector - Mechanical System Not Responding Properly
→injectorSPN652-FMI8SPN 652 FMI 8: Cylinder 2 Injector - Abnormal Frequency, Pulse Width or Period
→injectorSPN652-FMI9SPN 652 FMI 9: Cylinder 2 Injector - Abnormal Update Rate
→injectorSPN652-FMI10SPN 652 FMI 10: Cylinder 2 Injector - Abnormal Rate of Change
→injectorSPN652-FMI11SPN 652 FMI 11: Cylinder 2 Injector - Root Cause Not Known
→injectorSPN652-FMI12SPN 652 FMI 12: Cylinder 2 Injector - Bad Intelligent Device or Component
→injectorSPN652-FMI13SPN 652 FMI 13: Cylinder 2 Injector - Out of Calibration
→injectorSPN652-FMI14SPN 652 FMI 14: Cylinder 2 Injector - Special Instructions
→injectorSPN652-FMI15SPN 652 FMI 15: Cylinder 2 Injector - Above Normal Range - Least Severe
→injectorSPN652-FMI16SPN 652 FMI 16: Cylinder 2 Injector - Above Normal Range - Moderately Severe
→injectorSPN652-FMI17SPN 652 FMI 17: Cylinder 2 Injector - Below Normal Range - Least Severe
→injectorSPN652-FMI18SPN 652 FMI 18: Cylinder 2 Injector - Below Normal Range - Moderately Severe
→injectorSPN652-FMI19SPN 652 FMI 19: Cylinder 2 Injector - Received Network Data In Error
→injectorSPN652-FMI31SPN 652 FMI 31: Cylinder 2 Injector - Condition Exists
→injectorSPN653-FMI0SPN 653 FMI 0: Cylinder 3 Injector - Data Valid But Above Normal Operational Range
→injectorSPN653-FMI1SPN 653 FMI 1: Cylinder 3 Injector - Data Valid But Below Normal Operational Range
→injectorSPN653-FMI2SPN 653 FMI 2: Cylinder 3 Injector - Data Erratic, Intermittent or Incorrect
→injectorSPN653-FMI3SPN 653 FMI 3: Cylinder 3 Injector - Voltage Above Normal or Shorted High
→injectorSPN653-FMI4SPN 653 FMI 4: Cylinder 3 Injector - Voltage Below Normal or Shorted Low
→injectorSPN653-FMI5SPN 653 FMI 5: Cylinder 3 Injector - Current Below Normal or Open Circuit
→injectorSPN653-FMI6SPN 653 FMI 6: Cylinder 3 Injector - Current Above Normal or Grounded Circuit
→injectorSPN653-FMI7SPN 653 FMI 7: Cylinder 3 Injector - Mechanical System Not Responding Properly
→injectorSPN653-FMI8SPN 653 FMI 8: Cylinder 3 Injector - Abnormal Frequency, Pulse Width or Period
→injectorSPN653-FMI9SPN 653 FMI 9: Cylinder 3 Injector - Abnormal Update Rate
→injectorSPN653-FMI10SPN 653 FMI 10: Cylinder 3 Injector - Abnormal Rate of Change
→injectorSPN653-FMI11SPN 653 FMI 11: Cylinder 3 Injector - Root Cause Not Known
→injectorSPN653-FMI12SPN 653 FMI 12: Cylinder 3 Injector - Bad Intelligent Device or Component
→injectorSPN653-FMI13SPN 653 FMI 13: Cylinder 3 Injector - Out of Calibration
→injectorSPN653-FMI14SPN 653 FMI 14: Cylinder 3 Injector - Special Instructions
→injectorSPN653-FMI15SPN 653 FMI 15: Cylinder 3 Injector - Above Normal Range - Least Severe
→injectorSPN653-FMI16SPN 653 FMI 16: Cylinder 3 Injector - Above Normal Range - Moderately Severe
→injectorSPN653-FMI17SPN 653 FMI 17: Cylinder 3 Injector - Below Normal Range - Least Severe
→injectorSPN653-FMI18SPN 653 FMI 18: Cylinder 3 Injector - Below Normal Range - Moderately Severe
→injectorSPN653-FMI19SPN 653 FMI 19: Cylinder 3 Injector - Received Network Data In Error
→injectorSPN653-FMI31SPN 653 FMI 31: Cylinder 3 Injector - Condition Exists
→injectorSPN654-FMI0SPN 654 FMI 0: Cylinder 4 Injector - Data Valid But Above Normal Operational Range
→injectorSPN654-FMI1SPN 654 FMI 1: Cylinder 4 Injector - Data Valid But Below Normal Operational Range
→injectorSPN654-FMI2SPN 654 FMI 2: Cylinder 4 Injector - Data Erratic, Intermittent or Incorrect
→injectorSPN654-FMI3SPN 654 FMI 3: Cylinder 4 Injector - Voltage Above Normal or Shorted High
→injectorSPN654-FMI4SPN 654 FMI 4: Cylinder 4 Injector - Voltage Below Normal or Shorted Low
→injectorSPN654-FMI5SPN 654 FMI 5: Cylinder 4 Injector - Current Below Normal or Open Circuit
→injectorSPN654-FMI6SPN 654 FMI 6: Cylinder 4 Injector - Current Above Normal or Grounded Circuit
→injectorSPN654-FMI7SPN 654 FMI 7: Cylinder 4 Injector - Mechanical System Not Responding Properly
→injectorSPN654-FMI8SPN 654 FMI 8: Cylinder 4 Injector - Abnormal Frequency, Pulse Width or Period
→injectorSPN654-FMI9SPN 654 FMI 9: Cylinder 4 Injector - Abnormal Update Rate
→injectorSPN654-FMI10SPN 654 FMI 10: Cylinder 4 Injector - Abnormal Rate of Change
→injectorSPN654-FMI11SPN 654 FMI 11: Cylinder 4 Injector - Root Cause Not Known
→injectorSPN654-FMI12SPN 654 FMI 12: Cylinder 4 Injector - Bad Intelligent Device or Component
→injectorSPN654-FMI13SPN 654 FMI 13: Cylinder 4 Injector - Out of Calibration
→injectorSPN654-FMI14SPN 654 FMI 14: Cylinder 4 Injector - Special Instructions
→injectorSPN654-FMI15SPN 654 FMI 15: Cylinder 4 Injector - Above Normal Range - Least Severe
→injectorSPN654-FMI16SPN 654 FMI 16: Cylinder 4 Injector - Above Normal Range - Moderately Severe
→injectorSPN654-FMI17SPN 654 FMI 17: Cylinder 4 Injector - Below Normal Range - Least Severe
→injectorSPN654-FMI18SPN 654 FMI 18: Cylinder 4 Injector - Below Normal Range - Moderately Severe
→injectorSPN654-FMI19SPN 654 FMI 19: Cylinder 4 Injector - Received Network Data In Error
→injectorSPN654-FMI31SPN 654 FMI 31: Cylinder 4 Injector - Condition Exists
→injectorSPN655-FMI0SPN 655 FMI 0: Cylinder 5 Injector - Data Valid But Above Normal Operational Range
→injectorSPN655-FMI1SPN 655 FMI 1: Cylinder 5 Injector - Data Valid But Below Normal Operational Range
→injectorSPN655-FMI2SPN 655 FMI 2: Cylinder 5 Injector - Data Erratic, Intermittent or Incorrect
→injectorSPN655-FMI3SPN 655 FMI 3: Cylinder 5 Injector - Voltage Above Normal or Shorted High
→injectorSPN655-FMI4SPN 655 FMI 4: Cylinder 5 Injector - Voltage Below Normal or Shorted Low
→injectorSPN655-FMI5SPN 655 FMI 5: Cylinder 5 Injector - Current Below Normal or Open Circuit
→injectorSPN655-FMI6SPN 655 FMI 6: Cylinder 5 Injector - Current Above Normal or Grounded Circuit
→injectorSPN655-FMI7SPN 655 FMI 7: Cylinder 5 Injector - Mechanical System Not Responding Properly
→injectorSPN655-FMI8SPN 655 FMI 8: Cylinder 5 Injector - Abnormal Frequency, Pulse Width or Period
→injectorSPN655-FMI9SPN 655 FMI 9: Cylinder 5 Injector - Abnormal Update Rate
→injectorSPN655-FMI10SPN 655 FMI 10: Cylinder 5 Injector - Abnormal Rate of Change
→injectorSPN655-FMI11SPN 655 FMI 11: Cylinder 5 Injector - Root Cause Not Known
→injectorSPN655-FMI12SPN 655 FMI 12: Cylinder 5 Injector - Bad Intelligent Device or Component
→injectorSPN655-FMI13SPN 655 FMI 13: Cylinder 5 Injector - Out of Calibration
→injectorSPN655-FMI14SPN 655 FMI 14: Cylinder 5 Injector - Special Instructions
→injectorSPN655-FMI15SPN 655 FMI 15: Cylinder 5 Injector - Above Normal Range - Least Severe
→injectorSPN655-FMI16SPN 655 FMI 16: Cylinder 5 Injector - Above Normal Range - Moderately Severe
→injectorSPN655-FMI17SPN 655 FMI 17: Cylinder 5 Injector - Below Normal Range - Least Severe
→injectorSPN655-FMI18SPN 655 FMI 18: Cylinder 5 Injector - Below Normal Range - Moderately Severe
→injectorSPN655-FMI19SPN 655 FMI 19: Cylinder 5 Injector - Received Network Data In Error
→injectorSPN655-FMI31SPN 655 FMI 31: Cylinder 5 Injector - Condition Exists
→injectorSPN656-FMI0SPN 656 FMI 0: Cylinder 6 Injector - Data Valid But Above Normal Operational Range
→injectorSPN656-FMI1SPN 656 FMI 1: Cylinder 6 Injector - Data Valid But Below Normal Operational Range
→injectorSPN656-FMI2SPN 656 FMI 2: Cylinder 6 Injector - Data Erratic, Intermittent or Incorrect
→injectorSPN656-FMI3SPN 656 FMI 3: Cylinder 6 Injector - Voltage Above Normal or Shorted High
→injectorSPN656-FMI4SPN 656 FMI 4: Cylinder 6 Injector - Voltage Below Normal or Shorted Low
→injectorSPN656-FMI5SPN 656 FMI 5: Cylinder 6 Injector - Current Below Normal or Open Circuit
→injectorSPN656-FMI6SPN 656 FMI 6: Cylinder 6 Injector - Current Above Normal or Grounded Circuit
→injectorSPN656-FMI7SPN 656 FMI 7: Cylinder 6 Injector - Mechanical System Not Responding Properly
→injectorSPN656-FMI8SPN 656 FMI 8: Cylinder 6 Injector - Abnormal Frequency, Pulse Width or Period
→injectorSPN656-FMI9SPN 656 FMI 9: Cylinder 6 Injector - Abnormal Update Rate
→injectorSPN656-FMI10SPN 656 FMI 10: Cylinder 6 Injector - Abnormal Rate of Change
→injectorSPN656-FMI11SPN 656 FMI 11: Cylinder 6 Injector - Root Cause Not Known
→injectorSPN656-FMI12SPN 656 FMI 12: Cylinder 6 Injector - Bad Intelligent Device or Component
→injectorSPN656-FMI13SPN 656 FMI 13: Cylinder 6 Injector - Out of Calibration
→injectorSPN656-FMI14SPN 656 FMI 14: Cylinder 6 Injector - Special Instructions
→injectorSPN656-FMI15SPN 656 FMI 15: Cylinder 6 Injector - Above Normal Range - Least Severe
→injectorSPN656-FMI16SPN 656 FMI 16: Cylinder 6 Injector - Above Normal Range - Moderately Severe
→injectorSPN656-FMI17SPN 656 FMI 17: Cylinder 6 Injector - Below Normal Range - Least Severe
→injectorSPN656-FMI18SPN 656 FMI 18: Cylinder 6 Injector - Below Normal Range - Moderately Severe
→injectorSPN656-FMI19SPN 656 FMI 19: Cylinder 6 Injector - Received Network Data In Error
→injectorSPN656-FMI31SPN 656 FMI 31: Cylinder 6 Injector - Condition Exists
→timingSPN723-FMI0SPN 723 FMI 0: Engine Crankshaft Speed/Position - Data Valid But Above Normal Operational Range
→timingSPN723-FMI1SPN 723 FMI 1: Engine Crankshaft Speed/Position - Data Valid But Below Normal Operational Range
→timingSPN723-FMI2SPN 723 FMI 2: Engine Crankshaft Speed/Position - Data Erratic, Intermittent or Incorrect
→timingSPN723-FMI3SPN 723 FMI 3: Engine Crankshaft Speed/Position - Voltage Above Normal or Shorted High
→timingSPN723-FMI4SPN 723 FMI 4: Engine Crankshaft Speed/Position - Voltage Below Normal or Shorted Low
→timingSPN723-FMI5SPN 723 FMI 5: Engine Crankshaft Speed/Position - Current Below Normal or Open Circuit
→timingSPN723-FMI6SPN 723 FMI 6: Engine Crankshaft Speed/Position - Current Above Normal or Grounded Circuit
→timingSPN723-FMI7SPN 723 FMI 7: Engine Crankshaft Speed/Position - Mechanical System Not Responding Properly
→timingSPN723-FMI8SPN 723 FMI 8: Engine Crankshaft Speed/Position - Abnormal Frequency, Pulse Width or Period
→timingSPN723-FMI9SPN 723 FMI 9: Engine Crankshaft Speed/Position - Abnormal Update Rate
→timingSPN723-FMI10SPN 723 FMI 10: Engine Crankshaft Speed/Position - Abnormal Rate of Change
→timingSPN723-FMI11SPN 723 FMI 11: Engine Crankshaft Speed/Position - Root Cause Not Known
→timingSPN723-FMI12SPN 723 FMI 12: Engine Crankshaft Speed/Position - Bad Intelligent Device or Component
→timingSPN723-FMI13SPN 723 FMI 13: Engine Crankshaft Speed/Position - Out of Calibration
→timingSPN723-FMI14SPN 723 FMI 14: Engine Crankshaft Speed/Position - Special Instructions
→timingSPN723-FMI15SPN 723 FMI 15: Engine Crankshaft Speed/Position - Above Normal Range - Least Severe
→timingSPN723-FMI16SPN 723 FMI 16: Engine Crankshaft Speed/Position - Above Normal Range - Moderately Severe
→timingSPN723-FMI17SPN 723 FMI 17: Engine Crankshaft Speed/Position - Below Normal Range - Least Severe
→timingSPN723-FMI18SPN 723 FMI 18: Engine Crankshaft Speed/Position - Below Normal Range - Moderately Severe
→timingSPN723-FMI19SPN 723 FMI 19: Engine Crankshaft Speed/Position - Received Network Data In Error
→timingSPN723-FMI31SPN 723 FMI 31: Engine Crankshaft Speed/Position - Condition Exists
→engine_controlSPN1109-FMI0SPN 1109 FMI 0: Engine Protection System Shutdown - Data Valid But Above Normal Operational Range
→engine_controlSPN1109-FMI1SPN 1109 FMI 1: Engine Protection System Shutdown - Data Valid But Below Normal Operational Range
→engine_controlSPN1109-FMI2SPN 1109 FMI 2: Engine Protection System Shutdown - Data Erratic, Intermittent or Incorrect
→engine_controlSPN1109-FMI3SPN 1109 FMI 3: Engine Protection System Shutdown - Voltage Above Normal or Shorted High
→engine_controlSPN1109-FMI4SPN 1109 FMI 4: Engine Protection System Shutdown - Voltage Below Normal or Shorted Low
→engine_controlSPN1109-FMI5SPN 1109 FMI 5: Engine Protection System Shutdown - Current Below Normal or Open Circuit
→engine_controlSPN1109-FMI6SPN 1109 FMI 6: Engine Protection System Shutdown - Current Above Normal or Grounded Circuit
→engine_controlSPN1109-FMI7SPN 1109 FMI 7: Engine Protection System Shutdown - Mechanical System Not Responding Properly
→engine_controlSPN1109-FMI8SPN 1109 FMI 8: Engine Protection System Shutdown - Abnormal Frequency, Pulse Width or Period
→engine_controlSPN1109-FMI9SPN 1109 FMI 9: Engine Protection System Shutdown - Abnormal Update Rate
→engine_controlSPN1109-FMI10SPN 1109 FMI 10: Engine Protection System Shutdown - Abnormal Rate of Change
→engine_controlSPN1109-FMI11SPN 1109 FMI 11: Engine Protection System Shutdown - Root Cause Not Known
→engine_controlSPN1109-FMI12SPN 1109 FMI 12: Engine Protection System Shutdown - Bad Intelligent Device or Component
→engine_controlSPN1109-FMI13SPN 1109 FMI 13: Engine Protection System Shutdown - Out of Calibration
→engine_controlSPN1109-FMI14SPN 1109 FMI 14: Engine Protection System Shutdown - Special Instructions
→engine_controlSPN1109-FMI15SPN 1109 FMI 15: Engine Protection System Shutdown - Above Normal Range - Least Severe
→engine_controlSPN1109-FMI16SPN 1109 FMI 16: Engine Protection System Shutdown - Above Normal Range - Moderately Severe
→engine_controlSPN1109-FMI17SPN 1109 FMI 17: Engine Protection System Shutdown - Below Normal Range - Least Severe
→engine_controlSPN1109-FMI18SPN 1109 FMI 18: Engine Protection System Shutdown - Below Normal Range - Moderately Severe
→engine_controlSPN1109-FMI19SPN 1109 FMI 19: Engine Protection System Shutdown - Received Network Data In Error
→engine_controlSPN1109-FMI31SPN 1109 FMI 31: Engine Protection System Shutdown - Condition Exists
→misfireSPN1322-FMI0SPN 1322 FMI 0: Engine Misfire Count - Data Valid But Above Normal Operational Range
→misfireSPN1322-FMI1SPN 1322 FMI 1: Engine Misfire Count - Data Valid But Below Normal Operational Range
→misfireSPN1322-FMI2SPN 1322 FMI 2: Engine Misfire Count - Data Erratic, Intermittent or Incorrect
→misfireSPN1322-FMI3SPN 1322 FMI 3: Engine Misfire Count - Voltage Above Normal or Shorted High
→misfireSPN1322-FMI4SPN 1322 FMI 4: Engine Misfire Count - Voltage Below Normal or Shorted Low
→misfireSPN1322-FMI5SPN 1322 FMI 5: Engine Misfire Count - Current Below Normal or Open Circuit
→misfireSPN1322-FMI6SPN 1322 FMI 6: Engine Misfire Count - Current Above Normal or Grounded Circuit
→misfireSPN1322-FMI7SPN 1322 FMI 7: Engine Misfire Count - Mechanical System Not Responding Properly
→misfireSPN1322-FMI8SPN 1322 FMI 8: Engine Misfire Count - Abnormal Frequency, Pulse Width or Period
→misfireSPN1322-FMI9SPN 1322 FMI 9: Engine Misfire Count - Abnormal Update Rate
→misfireSPN1322-FMI10SPN 1322 FMI 10: Engine Misfire Count - Abnormal Rate of Change
→misfireSPN1322-FMI11SPN 1322 FMI 11: Engine Misfire Count - Root Cause Not Known
→misfireSPN1322-FMI12SPN 1322 FMI 12: Engine Misfire Count - Bad Intelligent Device or Component
→misfireSPN1322-FMI13SPN 1322 FMI 13: Engine Misfire Count - Out of Calibration
→misfireSPN1322-FMI14SPN 1322 FMI 14: Engine Misfire Count - Special Instructions
→misfireSPN1322-FMI15SPN 1322 FMI 15: Engine Misfire Count - Above Normal Range - Least Severe
→misfireSPN1322-FMI16SPN 1322 FMI 16: Engine Misfire Count - Above Normal Range - Moderately Severe
→misfireSPN1322-FMI17SPN 1322 FMI 17: Engine Misfire Count - Below Normal Range - Least Severe
→misfireSPN1322-FMI18SPN 1322 FMI 18: Engine Misfire Count - Below Normal Range - Moderately Severe
→misfireSPN1322-FMI19SPN 1322 FMI 19: Engine Misfire Count - Received Network Data In Error
→misfireSPN1322-FMI31SPN 1322 FMI 31: Engine Misfire Count - Condition Exists
→engine_controlSPN1569-FMI0SPN 1569 FMI 0: Engine Protection Torque Derate - Data Valid But Above Normal Operational Range
→engine_controlSPN1569-FMI1SPN 1569 FMI 1: Engine Protection Torque Derate - Data Valid But Below Normal Operational Range
→engine_controlSPN1569-FMI2SPN 1569 FMI 2: Engine Protection Torque Derate - Data Erratic, Intermittent or Incorrect
→engine_controlSPN1569-FMI3SPN 1569 FMI 3: Engine Protection Torque Derate - Voltage Above Normal or Shorted High
→engine_controlSPN1569-FMI4SPN 1569 FMI 4: Engine Protection Torque Derate - Voltage Below Normal or Shorted Low
→engine_controlSPN1569-FMI5SPN 1569 FMI 5: Engine Protection Torque Derate - Current Below Normal or Open Circuit
→engine_controlSPN1569-FMI6SPN 1569 FMI 6: Engine Protection Torque Derate - Current Above Normal or Grounded Circuit
→engine_controlSPN1569-FMI7SPN 1569 FMI 7: Engine Protection Torque Derate - Mechanical System Not Responding Properly
→engine_controlSPN1569-FMI8SPN 1569 FMI 8: Engine Protection Torque Derate - Abnormal Frequency, Pulse Width or Period
→engine_controlSPN1569-FMI9SPN 1569 FMI 9: Engine Protection Torque Derate - Abnormal Update Rate
→engine_controlSPN1569-FMI10SPN 1569 FMI 10: Engine Protection Torque Derate - Abnormal Rate of Change
→engine_controlSPN1569-FMI11SPN 1569 FMI 11: Engine Protection Torque Derate - Root Cause Not Known
→engine_controlSPN1569-FMI12SPN 1569 FMI 12: Engine Protection Torque Derate - Bad Intelligent Device or Component
→engine_controlSPN1569-FMI13SPN 1569 FMI 13: Engine Protection Torque Derate - Out of Calibration
→engine_controlSPN1569-FMI14SPN 1569 FMI 14: Engine Protection Torque Derate - Special Instructions
→engine_controlSPN1569-FMI15SPN 1569 FMI 15: Engine Protection Torque Derate - Above Normal Range - Least Severe
→engine_controlSPN1569-FMI16SPN 1569 FMI 16: Engine Protection Torque Derate - Above Normal Range - Moderately Severe
→engine_controlSPN1569-FMI17SPN 1569 FMI 17: Engine Protection Torque Derate - Below Normal Range - Least Severe
→engine_controlSPN1569-FMI18SPN 1569 FMI 18: Engine Protection Torque Derate - Below Normal Range - Moderately Severe
→engine_controlSPN1569-FMI19SPN 1569 FMI 19: Engine Protection Torque Derate - Received Network Data In Error
→engine_controlSPN1569-FMI31SPN 1569 FMI 31: Engine Protection Torque Derate - Condition Exists
→scrSPN1761-FMI0SPN 1761 FMI 0: DEF Tank Level - Data Valid But Above Normal Operational Range
→scrSPN1761-FMI1SPN 1761 FMI 1: DEF Tank Level - Data Valid But Below Normal Operational Range
→scrSPN1761-FMI2SPN 1761 FMI 2: DEF Tank Level - Data Erratic, Intermittent or Incorrect
→scrSPN1761-FMI3SPN 1761 FMI 3: DEF Tank Level - Voltage Above Normal or Shorted High
→scrSPN1761-FMI4SPN 1761 FMI 4: DEF Tank Level - Voltage Below Normal or Shorted Low
→scrSPN1761-FMI5SPN 1761 FMI 5: DEF Tank Level - Current Below Normal or Open Circuit
→scrSPN1761-FMI6SPN 1761 FMI 6: DEF Tank Level - Current Above Normal or Grounded Circuit
→scrSPN1761-FMI7SPN 1761 FMI 7: DEF Tank Level - Mechanical System Not Responding Properly
→scrSPN1761-FMI8SPN 1761 FMI 8: DEF Tank Level - Abnormal Frequency, Pulse Width or Period
→scrSPN1761-FMI9SPN 1761 FMI 9: DEF Tank Level - Abnormal Update Rate
→scrSPN1761-FMI10SPN 1761 FMI 10: DEF Tank Level - Abnormal Rate of Change
→scrSPN1761-FMI11SPN 1761 FMI 11: DEF Tank Level - Root Cause Not Known
→scrSPN1761-FMI12SPN 1761 FMI 12: DEF Tank Level - Bad Intelligent Device or Component
→scrSPN1761-FMI13SPN 1761 FMI 13: DEF Tank Level - Out of Calibration
→scrSPN1761-FMI14SPN 1761 FMI 14: DEF Tank Level - Special Instructions
→scrSPN1761-FMI15SPN 1761 FMI 15: DEF Tank Level - Above Normal Range - Least Severe
→scrSPN1761-FMI16SPN 1761 FMI 16: DEF Tank Level - Above Normal Range - Moderately Severe
→scrSPN1761-FMI17SPN 1761 FMI 17: DEF Tank Level - Below Normal Range - Least Severe
→scrSPN1761-FMI18SPN 1761 FMI 18: DEF Tank Level - Below Normal Range - Moderately Severe
→scrSPN1761-FMI19SPN 1761 FMI 19: DEF Tank Level - Received Network Data In Error
→scrSPN1761-FMI31SPN 1761 FMI 31: DEF Tank Level - Condition Exists
→scrSPN3031-FMI0SPN 3031 FMI 0: DEF Tank Temperature - Data Valid But Above Normal Operational Range
→scrSPN3031-FMI1SPN 3031 FMI 1: DEF Tank Temperature - Data Valid But Below Normal Operational Range
→scrSPN3031-FMI2SPN 3031 FMI 2: DEF Tank Temperature - Data Erratic, Intermittent or Incorrect
→scrSPN3031-FMI3SPN 3031 FMI 3: DEF Tank Temperature - Voltage Above Normal or Shorted High
→scrSPN3031-FMI4SPN 3031 FMI 4: DEF Tank Temperature - Voltage Below Normal or Shorted Low
→scrSPN3031-FMI5SPN 3031 FMI 5: DEF Tank Temperature - Current Below Normal or Open Circuit
→scrSPN3031-FMI6SPN 3031 FMI 6: DEF Tank Temperature - Current Above Normal or Grounded Circuit
→scrSPN3031-FMI7SPN 3031 FMI 7: DEF Tank Temperature - Mechanical System Not Responding Properly
→scrSPN3031-FMI8SPN 3031 FMI 8: DEF Tank Temperature - Abnormal Frequency, Pulse Width or Period
→scrSPN3031-FMI9SPN 3031 FMI 9: DEF Tank Temperature - Abnormal Update Rate
→scrSPN3031-FMI10SPN 3031 FMI 10: DEF Tank Temperature - Abnormal Rate of Change
→scrSPN3031-FMI11SPN 3031 FMI 11: DEF Tank Temperature - Root Cause Not Known
→scrSPN3031-FMI12SPN 3031 FMI 12: DEF Tank Temperature - Bad Intelligent Device or Component
→scrSPN3031-FMI13SPN 3031 FMI 13: DEF Tank Temperature - Out of Calibration
→scrSPN3031-FMI14SPN 3031 FMI 14: DEF Tank Temperature - Special Instructions
→scrSPN3031-FMI15SPN 3031 FMI 15: DEF Tank Temperature - Above Normal Range - Least Severe
→scrSPN3031-FMI16SPN 3031 FMI 16: DEF Tank Temperature - Above Normal Range - Moderately Severe
→scrSPN3031-FMI17SPN 3031 FMI 17: DEF Tank Temperature - Below Normal Range - Least Severe
→scrSPN3031-FMI18SPN 3031 FMI 18: DEF Tank Temperature - Below Normal Range - Moderately Severe
→scrSPN3031-FMI19SPN 3031 FMI 19: DEF Tank Temperature - Received Network Data In Error
→scrSPN3031-FMI31SPN 3031 FMI 31: DEF Tank Temperature - Condition Exists
→scrSPN3216-FMI0SPN 3216 FMI 0: NOx Sensor Intake - Data Valid But Above Normal Operational Range
→scrSPN3216-FMI1SPN 3216 FMI 1: NOx Sensor Intake - Data Valid But Below Normal Operational Range
→scrSPN3216-FMI2SPN 3216 FMI 2: NOx Sensor Intake - Data Erratic, Intermittent or Incorrect
→scrSPN3216-FMI3SPN 3216 FMI 3: NOx Sensor Intake - Voltage Above Normal or Shorted High
→scrSPN3216-FMI4SPN 3216 FMI 4: NOx Sensor Intake - Voltage Below Normal or Shorted Low
→scrSPN3216-FMI5SPN 3216 FMI 5: NOx Sensor Intake - Current Below Normal or Open Circuit
→scrSPN3216-FMI6SPN 3216 FMI 6: NOx Sensor Intake - Current Above Normal or Grounded Circuit
→scrSPN3216-FMI7SPN 3216 FMI 7: NOx Sensor Intake - Mechanical System Not Responding Properly
→scrSPN3216-FMI8SPN 3216 FMI 8: NOx Sensor Intake - Abnormal Frequency, Pulse Width or Period
→scrSPN3216-FMI9SPN 3216 FMI 9: NOx Sensor Intake - Abnormal Update Rate
→scrSPN3216-FMI10SPN 3216 FMI 10: NOx Sensor Intake - Abnormal Rate of Change
→scrSPN3216-FMI11SPN 3216 FMI 11: NOx Sensor Intake - Root Cause Not Known
→scrSPN3216-FMI12SPN 3216 FMI 12: NOx Sensor Intake - Bad Intelligent Device or Component
→scrSPN3216-FMI13SPN 3216 FMI 13: NOx Sensor Intake - Out of Calibration
→scrSPN3216-FMI14SPN 3216 FMI 14: NOx Sensor Intake - Special Instructions
→scrSPN3216-FMI15SPN 3216 FMI 15: NOx Sensor Intake - Above Normal Range - Least Severe
→scrSPN3216-FMI16SPN 3216 FMI 16: NOx Sensor Intake - Above Normal Range - Moderately Severe
→scrSPN3216-FMI17SPN 3216 FMI 17: NOx Sensor Intake - Below Normal Range - Least Severe
→scrSPN3216-FMI18SPN 3216 FMI 18: NOx Sensor Intake - Below Normal Range - Moderately Severe
→scrSPN3216-FMI19SPN 3216 FMI 19: NOx Sensor Intake - Received Network Data In Error
→scrSPN3216-FMI31SPN 3216 FMI 31: NOx Sensor Intake - Condition Exists
→scrSPN3226-FMI0SPN 3226 FMI 0: NOx Sensor Outlet - Data Valid But Above Normal Operational Range
→scrSPN3226-FMI1SPN 3226 FMI 1: NOx Sensor Outlet - Data Valid But Below Normal Operational Range
→scrSPN3226-FMI2SPN 3226 FMI 2: NOx Sensor Outlet - Data Erratic, Intermittent or Incorrect
→scrSPN3226-FMI3SPN 3226 FMI 3: NOx Sensor Outlet - Voltage Above Normal or Shorted High
→scrSPN3226-FMI4SPN 3226 FMI 4: NOx Sensor Outlet - Voltage Below Normal or Shorted Low
→scrSPN3226-FMI5SPN 3226 FMI 5: NOx Sensor Outlet - Current Below Normal or Open Circuit
→scrSPN3226-FMI6SPN 3226 FMI 6: NOx Sensor Outlet - Current Above Normal or Grounded Circuit
→scrSPN3226-FMI7SPN 3226 FMI 7: NOx Sensor Outlet - Mechanical System Not Responding Properly
→scrSPN3226-FMI8SPN 3226 FMI 8: NOx Sensor Outlet - Abnormal Frequency, Pulse Width or Period
→scrSPN3226-FMI9SPN 3226 FMI 9: NOx Sensor Outlet - Abnormal Update Rate
→scrSPN3226-FMI10SPN 3226 FMI 10: NOx Sensor Outlet - Abnormal Rate of Change
→scrSPN3226-FMI11SPN 3226 FMI 11: NOx Sensor Outlet - Root Cause Not Known
→scrSPN3226-FMI12SPN 3226 FMI 12: NOx Sensor Outlet - Bad Intelligent Device or Component
→scrSPN3226-FMI13SPN 3226 FMI 13: NOx Sensor Outlet - Out of Calibration
→scrSPN3226-FMI14SPN 3226 FMI 14: NOx Sensor Outlet - Special Instructions
→scrSPN3226-FMI15SPN 3226 FMI 15: NOx Sensor Outlet - Above Normal Range - Least Severe
→scrSPN3226-FMI16SPN 3226 FMI 16: NOx Sensor Outlet - Above Normal Range - Moderately Severe
→scrSPN3226-FMI17SPN 3226 FMI 17: NOx Sensor Outlet - Below Normal Range - Least Severe
→scrSPN3226-FMI18SPN 3226 FMI 18: NOx Sensor Outlet - Below Normal Range - Moderately Severe
→scrSPN3226-FMI19SPN 3226 FMI 19: NOx Sensor Outlet - Received Network Data In Error
→scrSPN3226-FMI31SPN 3226 FMI 31: NOx Sensor Outlet - Condition Exists
→dpfSPN3242-FMI0SPN 3242 FMI 0: DPF Intake Temperature - Data Valid But Above Normal Operational Range
→dpfSPN3242-FMI1SPN 3242 FMI 1: DPF Intake Temperature - Data Valid But Below Normal Operational Range
→dpfSPN3242-FMI2SPN 3242 FMI 2: DPF Intake Temperature - Data Erratic, Intermittent or Incorrect
→dpfSPN3242-FMI3SPN 3242 FMI 3: DPF Intake Temperature - Voltage Above Normal or Shorted High
→dpfSPN3242-FMI4SPN 3242 FMI 4: DPF Intake Temperature - Voltage Below Normal or Shorted Low
→dpfSPN3242-FMI5SPN 3242 FMI 5: DPF Intake Temperature - Current Below Normal or Open Circuit
→dpfSPN3242-FMI6SPN 3242 FMI 6: DPF Intake Temperature - Current Above Normal or Grounded Circuit
→dpfSPN3242-FMI7SPN 3242 FMI 7: DPF Intake Temperature - Mechanical System Not Responding Properly
→dpfSPN3242-FMI8SPN 3242 FMI 8: DPF Intake Temperature - Abnormal Frequency, Pulse Width or Period
→dpfSPN3242-FMI9SPN 3242 FMI 9: DPF Intake Temperature - Abnormal Update Rate
→dpfSPN3242-FMI10SPN 3242 FMI 10: DPF Intake Temperature - Abnormal Rate of Change
→dpfSPN3242-FMI11SPN 3242 FMI 11: DPF Intake Temperature - Root Cause Not Known
→dpfSPN3242-FMI12SPN 3242 FMI 12: DPF Intake Temperature - Bad Intelligent Device or Component
→dpfSPN3242-FMI13SPN 3242 FMI 13: DPF Intake Temperature - Out of Calibration
→dpfSPN3242-FMI14SPN 3242 FMI 14: DPF Intake Temperature - Special Instructions
→dpfSPN3242-FMI15SPN 3242 FMI 15: DPF Intake Temperature - Above Normal Range - Least Severe
→dpfSPN3242-FMI16SPN 3242 FMI 16: DPF Intake Temperature - Above Normal Range - Moderately Severe
→dpfSPN3242-FMI17SPN 3242 FMI 17: DPF Intake Temperature - Below Normal Range - Least Severe
→dpfSPN3242-FMI18SPN 3242 FMI 18: DPF Intake Temperature - Below Normal Range - Moderately Severe
→dpfSPN3242-FMI19SPN 3242 FMI 19: DPF Intake Temperature - Received Network Data In Error
→dpfSPN3242-FMI31SPN 3242 FMI 31: DPF Intake Temperature - Condition Exists
→dpfSPN3251-FMI0SPN 3251 FMI 0: DPF Differential Pressure - Data Valid But Above Normal Operational Range
→dpfSPN3251-FMI1SPN 3251 FMI 1: DPF Differential Pressure - Data Valid But Below Normal Operational Range
→dpfSPN3251-FMI2SPN 3251 FMI 2: DPF Differential Pressure - Data Erratic, Intermittent or Incorrect
→dpfSPN3251-FMI3SPN 3251 FMI 3: DPF Differential Pressure - Voltage Above Normal or Shorted High
→dpfSPN3251-FMI4SPN 3251 FMI 4: DPF Differential Pressure - Voltage Below Normal or Shorted Low
→dpfSPN3251-FMI5SPN 3251 FMI 5: DPF Differential Pressure - Current Below Normal or Open Circuit
→dpfSPN3251-FMI6SPN 3251 FMI 6: DPF Differential Pressure - Current Above Normal or Grounded Circuit
→dpfSPN3251-FMI7SPN 3251 FMI 7: DPF Differential Pressure - Mechanical System Not Responding Properly
→dpfSPN3251-FMI8SPN 3251 FMI 8: DPF Differential Pressure - Abnormal Frequency, Pulse Width or Period
→dpfSPN3251-FMI9SPN 3251 FMI 9: DPF Differential Pressure - Abnormal Update Rate
→dpfSPN3251-FMI10SPN 3251 FMI 10: DPF Differential Pressure - Abnormal Rate of Change
→dpfSPN3251-FMI11SPN 3251 FMI 11: DPF Differential Pressure - Root Cause Not Known
→dpfSPN3251-FMI12SPN 3251 FMI 12: DPF Differential Pressure - Bad Intelligent Device or Component
→dpfSPN3251-FMI13SPN 3251 FMI 13: DPF Differential Pressure - Out of Calibration
→dpfSPN3251-FMI14SPN 3251 FMI 14: DPF Differential Pressure - Special Instructions
→dpfSPN3251-FMI15SPN 3251 FMI 15: DPF Differential Pressure - Above Normal Range - Least Severe
→dpfSPN3251-FMI16SPN 3251 FMI 16: DPF Differential Pressure - Above Normal Range - Moderately Severe
→dpfSPN3251-FMI17SPN 3251 FMI 17: DPF Differential Pressure - Below Normal Range - Least Severe
→dpfSPN3251-FMI18SPN 3251 FMI 18: DPF Differential Pressure - Below Normal Range - Moderately Severe
→dpfSPN3251-FMI19SPN 3251 FMI 19: DPF Differential Pressure - Received Network Data In Error
→dpfSPN3251-FMI31SPN 3251 FMI 31: DPF Differential Pressure - Condition Exists
→scrSPN3361-FMI0SPN 3361 FMI 0: DEF Dosing Unit - Data Valid But Above Normal Operational Range
→scrSPN3361-FMI1SPN 3361 FMI 1: DEF Dosing Unit - Data Valid But Below Normal Operational Range
→scrSPN3361-FMI2SPN 3361 FMI 2: DEF Dosing Unit - Data Erratic, Intermittent or Incorrect
→scrSPN3361-FMI3SPN 3361 FMI 3: DEF Dosing Unit - Voltage Above Normal or Shorted High
→scrSPN3361-FMI4SPN 3361 FMI 4: DEF Dosing Unit - Voltage Below Normal or Shorted Low
→scrSPN3361-FMI5SPN 3361 FMI 5: DEF Dosing Unit - Current Below Normal or Open Circuit
→scrSPN3361-FMI6SPN 3361 FMI 6: DEF Dosing Unit - Current Above Normal or Grounded Circuit
→scrSPN3361-FMI7SPN 3361 FMI 7: DEF Dosing Unit - Mechanical System Not Responding Properly
→scrSPN3361-FMI8SPN 3361 FMI 8: DEF Dosing Unit - Abnormal Frequency, Pulse Width or Period
→scrSPN3361-FMI9SPN 3361 FMI 9: DEF Dosing Unit - Abnormal Update Rate
→scrSPN3361-FMI10SPN 3361 FMI 10: DEF Dosing Unit - Abnormal Rate of Change
→scrSPN3361-FMI11SPN 3361 FMI 11: DEF Dosing Unit - Root Cause Not Known
→scrSPN3361-FMI12SPN 3361 FMI 12: DEF Dosing Unit - Bad Intelligent Device or Component
→scrSPN3361-FMI13SPN 3361 FMI 13: DEF Dosing Unit - Out of Calibration
→scrSPN3361-FMI14SPN 3361 FMI 14: DEF Dosing Unit - Special Instructions
→scrSPN3361-FMI15SPN 3361 FMI 15: DEF Dosing Unit - Above Normal Range - Least Severe
→scrSPN3361-FMI16SPN 3361 FMI 16: DEF Dosing Unit - Above Normal Range - Moderately Severe
→scrSPN3361-FMI17SPN 3361 FMI 17: DEF Dosing Unit - Below Normal Range - Least Severe
→scrSPN3361-FMI18SPN 3361 FMI 18: DEF Dosing Unit - Below Normal Range - Moderately Severe
→scrSPN3361-FMI19SPN 3361 FMI 19: DEF Dosing Unit - Received Network Data In Error
→scrSPN3361-FMI31SPN 3361 FMI 31: DEF Dosing Unit - Condition Exists
→airSPN3464-FMI0SPN 3464 FMI 0: Engine Intake Throttle Position - Data Valid But Above Normal Operational Range
→airSPN3464-FMI1SPN 3464 FMI 1: Engine Intake Throttle Position - Data Valid But Below Normal Operational Range
→airSPN3464-FMI2SPN 3464 FMI 2: Engine Intake Throttle Position - Data Erratic, Intermittent or Incorrect
→airSPN3464-FMI3SPN 3464 FMI 3: Engine Intake Throttle Position - Voltage Above Normal or Shorted High
→airSPN3464-FMI4SPN 3464 FMI 4: Engine Intake Throttle Position - Voltage Below Normal or Shorted Low
→airSPN3464-FMI5SPN 3464 FMI 5: Engine Intake Throttle Position - Current Below Normal or Open Circuit
→airSPN3464-FMI6SPN 3464 FMI 6: Engine Intake Throttle Position - Current Above Normal or Grounded Circuit
→airSPN3464-FMI7SPN 3464 FMI 7: Engine Intake Throttle Position - Mechanical System Not Responding Properly
→airSPN3464-FMI8SPN 3464 FMI 8: Engine Intake Throttle Position - Abnormal Frequency, Pulse Width or Period
→airSPN3464-FMI9SPN 3464 FMI 9: Engine Intake Throttle Position - Abnormal Update Rate
→airSPN3464-FMI10SPN 3464 FMI 10: Engine Intake Throttle Position - Abnormal Rate of Change
→airSPN3464-FMI11SPN 3464 FMI 11: Engine Intake Throttle Position - Root Cause Not Known
→airSPN3464-FMI12SPN 3464 FMI 12: Engine Intake Throttle Position - Bad Intelligent Device or Component
→airSPN3464-FMI13SPN 3464 FMI 13: Engine Intake Throttle Position - Out of Calibration
→airSPN3464-FMI14SPN 3464 FMI 14: Engine Intake Throttle Position - Special Instructions
→airSPN3464-FMI15SPN 3464 FMI 15: Engine Intake Throttle Position - Above Normal Range - Least Severe
→airSPN3464-FMI16SPN 3464 FMI 16: Engine Intake Throttle Position - Above Normal Range - Moderately Severe
→airSPN3464-FMI17SPN 3464 FMI 17: Engine Intake Throttle Position - Below Normal Range - Least Severe
→airSPN3464-FMI18SPN 3464 FMI 18: Engine Intake Throttle Position - Below Normal Range - Moderately Severe
→airSPN3464-FMI19SPN 3464 FMI 19: Engine Intake Throttle Position - Received Network Data In Error
→airSPN3464-FMI31SPN 3464 FMI 31: Engine Intake Throttle Position - Condition Exists
→scrSPN3516-FMI0SPN 3516 FMI 0: DEF Quality Sensor - Data Valid But Above Normal Operational Range
→scrSPN3516-FMI1SPN 3516 FMI 1: DEF Quality Sensor - Data Valid But Below Normal Operational Range
→scrSPN3516-FMI2SPN 3516 FMI 2: DEF Quality Sensor - Data Erratic, Intermittent or Incorrect
→scrSPN3516-FMI3SPN 3516 FMI 3: DEF Quality Sensor - Voltage Above Normal or Shorted High
→scrSPN3516-FMI4SPN 3516 FMI 4: DEF Quality Sensor - Voltage Below Normal or Shorted Low
→scrSPN3516-FMI5SPN 3516 FMI 5: DEF Quality Sensor - Current Below Normal or Open Circuit
→scrSPN3516-FMI6SPN 3516 FMI 6: DEF Quality Sensor - Current Above Normal or Grounded Circuit
→scrSPN3516-FMI7SPN 3516 FMI 7: DEF Quality Sensor - Mechanical System Not Responding Properly
→scrSPN3516-FMI8SPN 3516 FMI 8: DEF Quality Sensor - Abnormal Frequency, Pulse Width or Period
→scrSPN3516-FMI9SPN 3516 FMI 9: DEF Quality Sensor - Abnormal Update Rate
→scrSPN3516-FMI10SPN 3516 FMI 10: DEF Quality Sensor - Abnormal Rate of Change
→scrSPN3516-FMI11SPN 3516 FMI 11: DEF Quality Sensor - Root Cause Not Known
→scrSPN3516-FMI12SPN 3516 FMI 12: DEF Quality Sensor - Bad Intelligent Device or Component
→scrSPN3516-FMI13SPN 3516 FMI 13: DEF Quality Sensor - Out of Calibration
→scrSPN3516-FMI14SPN 3516 FMI 14: DEF Quality Sensor - Special Instructions
→scrSPN3516-FMI15SPN 3516 FMI 15: DEF Quality Sensor - Above Normal Range - Least Severe
→scrSPN3516-FMI16SPN 3516 FMI 16: DEF Quality Sensor - Above Normal Range - Moderately Severe
→scrSPN3516-FMI17SPN 3516 FMI 17: DEF Quality Sensor - Below Normal Range - Least Severe
→scrSPN3516-FMI18SPN 3516 FMI 18: DEF Quality Sensor - Below Normal Range - Moderately Severe
→scrSPN3516-FMI19SPN 3516 FMI 19: DEF Quality Sensor - Received Network Data In Error
→scrSPN3516-FMI31SPN 3516 FMI 31: DEF Quality Sensor - Condition Exists
→scrSPN4094-FMI0SPN 4094 FMI 0: DEF Dosing System - Data Valid But Above Normal Operational Range
→scrSPN4094-FMI1SPN 4094 FMI 1: DEF Dosing System - Data Valid But Below Normal Operational Range
→scrSPN4094-FMI2SPN 4094 FMI 2: DEF Dosing System - Data Erratic, Intermittent or Incorrect
→scrSPN4094-FMI3SPN 4094 FMI 3: DEF Dosing System - Voltage Above Normal or Shorted High
→scrSPN4094-FMI4SPN 4094 FMI 4: DEF Dosing System - Voltage Below Normal or Shorted Low
→scrSPN4094-FMI5SPN 4094 FMI 5: DEF Dosing System - Current Below Normal or Open Circuit
→scrSPN4094-FMI6SPN 4094 FMI 6: DEF Dosing System - Current Above Normal or Grounded Circuit
→scrSPN4094-FMI7SPN 4094 FMI 7: DEF Dosing System - Mechanical System Not Responding Properly
→scrSPN4094-FMI8SPN 4094 FMI 8: DEF Dosing System - Abnormal Frequency, Pulse Width or Period
→scrSPN4094-FMI9SPN 4094 FMI 9: DEF Dosing System - Abnormal Update Rate
→scrSPN4094-FMI10SPN 4094 FMI 10: DEF Dosing System - Abnormal Rate of Change
→scrSPN4094-FMI11SPN 4094 FMI 11: DEF Dosing System - Root Cause Not Known
→scrSPN4094-FMI12SPN 4094 FMI 12: DEF Dosing System - Bad Intelligent Device or Component
→scrSPN4094-FMI13SPN 4094 FMI 13: DEF Dosing System - Out of Calibration
→scrSPN4094-FMI14SPN 4094 FMI 14: DEF Dosing System - Special Instructions
→scrSPN4094-FMI15SPN 4094 FMI 15: DEF Dosing System - Above Normal Range - Least Severe
→scrSPN4094-FMI16SPN 4094 FMI 16: DEF Dosing System - Above Normal Range - Moderately Severe
→scrSPN4094-FMI17SPN 4094 FMI 17: DEF Dosing System - Below Normal Range - Least Severe
→scrSPN4094-FMI18SPN 4094 FMI 18: DEF Dosing System - Below Normal Range - Moderately Severe
→scrSPN4094-FMI19SPN 4094 FMI 19: DEF Dosing System - Received Network Data In Error
→scrSPN4094-FMI31SPN 4094 FMI 31: DEF Dosing System - Condition Exists
→scrSPN4364-FMI0SPN 4364 FMI 0: SCR Conversion Efficiency - Data Valid But Above Normal Operational Range
→scrSPN4364-FMI1SPN 4364 FMI 1: SCR Conversion Efficiency - Data Valid But Below Normal Operational Range
→scrSPN4364-FMI2SPN 4364 FMI 2: SCR Conversion Efficiency - Data Erratic, Intermittent or Incorrect
→scrSPN4364-FMI3SPN 4364 FMI 3: SCR Conversion Efficiency - Voltage Above Normal or Shorted High
→scrSPN4364-FMI4SPN 4364 FMI 4: SCR Conversion Efficiency - Voltage Below Normal or Shorted Low
→scrSPN4364-FMI5SPN 4364 FMI 5: SCR Conversion Efficiency - Current Below Normal or Open Circuit
→scrSPN4364-FMI6SPN 4364 FMI 6: SCR Conversion Efficiency - Current Above Normal or Grounded Circuit
→scrSPN4364-FMI7SPN 4364 FMI 7: SCR Conversion Efficiency - Mechanical System Not Responding Properly
→scrSPN4364-FMI8SPN 4364 FMI 8: SCR Conversion Efficiency - Abnormal Frequency, Pulse Width or Period
→scrSPN4364-FMI9SPN 4364 FMI 9: SCR Conversion Efficiency - Abnormal Update Rate
→scrSPN4364-FMI10SPN 4364 FMI 10: SCR Conversion Efficiency - Abnormal Rate of Change
→scrSPN4364-FMI11SPN 4364 FMI 11: SCR Conversion Efficiency - Root Cause Not Known
→scrSPN4364-FMI12SPN 4364 FMI 12: SCR Conversion Efficiency - Bad Intelligent Device or Component
→scrSPN4364-FMI13SPN 4364 FMI 13: SCR Conversion Efficiency - Out of Calibration
→scrSPN4364-FMI14SPN 4364 FMI 14: SCR Conversion Efficiency - Special Instructions
→scrSPN4364-FMI15SPN 4364 FMI 15: SCR Conversion Efficiency - Above Normal Range - Least Severe
→scrSPN4364-FMI16SPN 4364 FMI 16: SCR Conversion Efficiency - Above Normal Range - Moderately Severe
→scrSPN4364-FMI17SPN 4364 FMI 17: SCR Conversion Efficiency - Below Normal Range - Least Severe
→scrSPN4364-FMI18SPN 4364 FMI 18: SCR Conversion Efficiency - Below Normal Range - Moderately Severe
→scrSPN4364-FMI19SPN 4364 FMI 19: SCR Conversion Efficiency - Received Network Data In Error
→scrSPN4364-FMI31SPN 4364 FMI 31: SCR Conversion Efficiency - Condition Exists
→Jump directly to concrete technical information
Open identity, application, diagnosis, measurement and evidence layers.
→SPN91-FMI2Open identity, application, diagnosis, measurement and evidence layers.
→SPN94-FMI1Open identity, application, diagnosis, measurement and evidence layers.
→SPN97-FMI15Open identity, application, diagnosis, measurement and evidence layers.
→SPN100-FMI1Open identity, application, diagnosis, measurement and evidence layers.
→SPN102-FMI1Open identity, application, diagnosis, measurement and evidence layers.
→SPN110-FMI0Open identity, application, diagnosis, measurement and evidence layers.
→SPN111-FMI1Open identity, application, diagnosis, measurement and evidence layers.
→Sources & freshness
Exact technical values, prices and failure rates are not invented without verified vehicle/manufacturer evidence.