What is the power rating of Cummins Onan QG 2800i 2.8HGLAA-8302A?
2.8 kW
The cited OEM source lists Rated power for Cummins Onan QG 2800i 2.8HGLAA-8302A as 2.8 kW.
Cummins Onan QG 2800i 2.8HGLAA-8302A — Rated power: 2.8 kW · Frequency: 60 Hz · Voltage: 120 V Sources, symptoms, measurements and verification on one page.
2.8 kW
The cited OEM source lists Rated power for Cummins Onan QG 2800i 2.8HGLAA-8302A as 2.8 kW.
60 Hz
The cited OEM source lists Frequency for Cummins Onan QG 2800i 2.8HGLAA-8302A as 60 Hz.
120 V
The cited OEM source lists Voltage for Cummins Onan QG 2800i 2.8HGLAA-8302A as 120 V.
23.3 A
The cited OEM source lists Current for Cummins Onan QG 2800i 2.8HGLAA-8302A as 23.3 A.
1
The cited OEM source lists Phase for Cummins Onan QG 2800i 2.8HGLAA-8302A as 1.
2445 rpm
The cited OEM source lists Minimum operating RPM for Cummins Onan QG 2800i 2.8HGLAA-8302A as 2445 rpm.
2900 rpm
The cited OEM source lists Maximum operating RPM for Cummins Onan QG 2800i 2.8HGLAA-8302A as 2900 rpm.
2800 W
The cited OEM source lists Output power for Cummins Onan QG 2800i 2.8HGLAA-8302A as 2800 W.
2.8 kW
60 Hz
120 V
23.3 A
1
2445 rpm
2900 rpm
2800 W
2.8 kW
60 Hz
120 V
QG 2800i 2.8HGLAA-8302A: OEM-published Rated power reference is 2.8 kW. Measurement/evaluation on the same configuration should use this published value as context; obtain any service tolerance from the VIN/serial-matched OEM procedure.
QG 2800i 2.8HGLAA-8302A: OEM-published Frequency reference is 60 Hz. Measurement/evaluation on the same configuration should use this published value as context; obtain any service tolerance from the VIN/serial-matched OEM procedure.
QG 2800i 2.8HGLAA-8302A: OEM-published Voltage reference is 120 V. Measurement/evaluation on the same configuration should use this published value as context; obtain any service tolerance from the VIN/serial-matched OEM procedure.
QG 2800i 2.8HGLAA-8302A: OEM-published Current reference is 23.3 A. Measurement/evaluation on the same configuration should use this published value as context; obtain any service tolerance from the VIN/serial-matched OEM procedure.
Output voltage/frequency instability or collapse under load
Low-oil/high-temperature shutdown or hard starting
J1939/remote-control communication issue
Compare output voltage, frequency, current and phase with the recorded rating; apply load-bank steps without exceeding the nameplate.
On variable-speed models, log rpm, inverter output, oil and temperature shutdown inputs at the event.
Separate engine-speed/governor faults from alternator/inverter output faults by correlating rpm with Hz/voltage deviation on the same time base.
Preserve self-diagnostic code, shutdown reason and actual load together.
Check voltage/frequency stability and shutdown recurrence at no-load, 25%, 50%, 75% and permitted full-load steps.
QG 2800i: exact maintenance interval, fluid-change quantity and torque procedure must be verified from OEM maintenance/service information matched to model year/VIN/serial number; unpublished service thresholds are not invented in this record.
QG 2800i: Evaluate engine/governor, alternator/inverter control and remote/J1939 interface together.
QG 2800i: Output voltage/frequency/current measurement.
QG 2800i: Engine speed / governor command.
QG 2800i: Oil-pressure or low-oil shutdown input.
QG 2800i: Engine-temperature shutdown input.
QG 2800i: Alternator/inverter regulation data.
QG 2800i: Remote/J1939 control state where fitted.
Only exact values published by the cited source are shown numerically. Pins, torque, pressure, resistance or service thresholds not publicly published are not invented; use the VIN/model-year/calibration-matched OEM service procedure.
Exact technical values, prices and failure rates are not invented without verified vehicle/manufacturer evidence.