What is the power rating of Cummins Onan QG5500 5.5HGJAD-6759?
5.5 kW
The cited OEM source lists Rated power for Cummins Onan QG5500 5.5HGJAD-6759 as 5.5 kW.
Cummins Onan QG5500 5.5HGJAD-6759 — Rated power: 5.5 kW · Frequency: 60 Hz · Voltage: 120/240 V Sources, symptoms, measurements and verification on one page.
5.5 kW
The cited OEM source lists Rated power for Cummins Onan QG5500 5.5HGJAD-6759 as 5.5 kW.
60 Hz
The cited OEM source lists Frequency for Cummins Onan QG5500 5.5HGJAD-6759 as 60 Hz.
120/240 V
The cited OEM source lists Voltage for Cummins Onan QG5500 5.5HGJAD-6759 as 120/240 V.
22.9 A
The cited OEM source lists Current for Cummins Onan QG5500 5.5HGJAD-6759 as 22.9 A.
1
The cited OEM source lists Phase for Cummins Onan QG5500 5.5HGJAD-6759 as 1.
5.5 kW
60 Hz
120/240 V
22.9 A
1
5.5 kW
60 Hz
120/240 V
QG5500 5.5HGJAD-6759: OEM-published Rated power reference is 5.5 kW. Measurement/evaluation on the same configuration should use this published value as context; obtain any service tolerance from the VIN/serial-matched OEM procedure.
QG5500 5.5HGJAD-6759: OEM-published Frequency reference is 60 Hz. Measurement/evaluation on the same configuration should use this published value as context; obtain any service tolerance from the VIN/serial-matched OEM procedure.
QG5500 5.5HGJAD-6759: OEM-published Voltage reference is 120/240 V. Measurement/evaluation on the same configuration should use this published value as context; obtain any service tolerance from the VIN/serial-matched OEM procedure.
QG5500 5.5HGJAD-6759: OEM-published Current reference is 22.9 A. Measurement/evaluation on the same configuration should use this published value as context; obtain any service tolerance from the VIN/serial-matched OEM procedure.
Output voltage/frequency instability or collapse under load
Low-oil/high-temperature shutdown or hard starting
J1939/remote-control communication issue
Compare output voltage, frequency, current and phase with the recorded rating; apply load-bank steps without exceeding the nameplate.
On variable-speed models, log rpm, inverter output, oil and temperature shutdown inputs at the event.
Separate engine-speed/governor faults from alternator/inverter output faults by correlating rpm with Hz/voltage deviation on the same time base.
Preserve self-diagnostic code, shutdown reason and actual load together.
Check voltage/frequency stability and shutdown recurrence at no-load, 25%, 50%, 75% and permitted full-load steps.
QG5500: exact maintenance interval, fluid-change quantity and torque procedure must be verified from OEM maintenance/service information matched to model year/VIN/serial number; unpublished service thresholds are not invented in this record.
QG5500: Evaluate engine/governor, alternator/inverter control and remote/J1939 interface together.
QG5500: Output voltage/frequency/current measurement.
QG5500: Engine speed / governor command.
QG5500: Oil-pressure or low-oil shutdown input.
QG5500: Engine-temperature shutdown input.
QG5500: Alternator/inverter regulation data.
QG5500: Remote/J1939 control state where fitted.
Only exact values published by the cited source are shown numerically. Pins, torque, pressure, resistance or service thresholds not publicly published are not invented; use the VIN/model-year/calibration-matched OEM service procedure.
Exact technical values, prices and failure rates are not invented without verified vehicle/manufacturer evidence.